Patient dosimetry for 131I-MIBG therapy for neuroendocrine tumours based on 123I-MIBG scans.

Eur J Nucl Med Mol Imaging

Department of Medical Physics and Radiation Protection, Ghent University, Proeftuinstraat 86, 9000 Ghent, Belgium.

Published: December 2002

Pre-therapeutic metaiodobenzylguanidine (MIBG) scans can be performed using labelling with either iodine-123 or iodine-131. (123)I-MIBG scans provide better image quality and count statistics, while (131)I-MIBG allows registration of tracer kinetics over a longer period. The aim of this study was to determine how much information about the (131)I-MIBG therapy total body dose according to the MIRD formalism can be gathered from (123)I-MIBG pre-therapy scans. Thirty-eight (131)I-MIBG therapies administered to a total of 15 patients suffering from neuroblastoma ( n=6), carcinoid tumours ( n=5), phaeochromocytoma ( n=3) and medullary thyroid carcinoma ( n=1) were included. The mean administered activity was 5.3 GBq (SD 2.4 GBq). Three biplanar (123)I-MIBG total body scans were taken only once before a series of therapies while three biplanar (131)I-MIBG scans were taken after each therapy. Attenuation correction was performed taking into account the difference in attenuation between (123)I and (131)I. Using the MIRD formalism, the total body dose to the patient was calculated on the basis of: (1) a single exponential fit drawn through the data from the (123)I-MIBG pre-therapy scans, (2) a bi-exponential fit through the combined data of (123)I-MIBG pre-therapy and (131)I-MIBG post-therapy scans. The mean total body dose calculated in our study was significantly higher for patients suffering from neuroblastoma (mean+/-SD 0.37+/-0.21 mGy/MBq) than for patients suffering from phaeochromocytoma (0.08+/-0.02 mGy/MBq), carcinoid tumours (0.07+/-0.01 mGy/MBq) and medullary thyroid carcinoma (0.09 mGy/MBq). The correlation coefficient between the dose calculated on the basis of the (123)I-MIBG pre-therapy scans and the subsequent (131)I-MIBG therapy was 0.93 when a correction factor of 1.26 was taken into account. When considering all following therapies, the correlation was 0.85 and the correction factor, 1.20. Our results show that it is feasible to use data from pre-therapy (123)I-MIBG scans to calculate the total body dose of the subsequent (131)I-MIBG therapy.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00259-002-0973-4DOI Listing

Publication Analysis

Top Keywords

total body
20
131i-mibg therapy
16
body dose
16
123i-mibg pre-therapy
16
123i-mibg scans
12
pre-therapy scans
12
patients suffering
12
scans
10
131i-mibg
8
123i-mibg
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!