Purpose: To evaluate how visual acuities at different distances correlate with results from defocus curves.

Setting: Department of Ophthalmology and Institute of Medical Physics, University of Vienna, Medical School, Vienna, and Department of Ophthalmology, Krankenhaus St. Pölten, St. Pölten, Austria.

Methods: This study comprised 15 eyes of 14 patients with a mean age of 67.9 years +/- 9.7 (SD) with a monofocal silicone intraocular lens (911A, Pharmacia). The best corrected distance visual acuity was determined at viewing distances of 6 m, 2 m, 1 m, 67 cm, 50 cm, 40 cm, and 33 cm using logMAR charts. Defocus curves were then evaluated from -3.0 to -0.5 diopter (D) at 0.5 D increments from the best distance correction at a viewing distance of 6 m.

Results: The mean distance visual acuity was logMAR 0.08 +/- 0.07. The visual acuity graph from the testing at different distances was above the defocus graph at all testing points. Comparison of the visual acuity results from the 2 tests revealed statistically significant differences in the range from 2 m (-0.5 D) to 33 cm (-3.0 D).

Conclusions: Results of defocus curves disregard the diminutions of minus glasses, the normally restricted viewing distance to 6 m for distance acuity determination, and in particular the physiological miosis caused by the near-point reaction.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0886-3350(02)01317-2DOI Listing

Publication Analysis

Top Keywords

visual acuity
16
defocus curves
12
comparison visual
8
visual acuities
8
acuities distances
8
distances defocus
8
department ophthalmology
8
distance visual
8
viewing distance
8
graph testing
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!