A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Bifluorophoric molecules as fluorescent beacons for antibody-antigen binding. | LitMetric

Bifluorophoric molecules as fluorescent beacons for antibody-antigen binding.

J Mol Recognit

Department of Pharmaceutics, University of Utah, Salt Lake City 84112, USA.

Published: June 2003

The quenching of fluorescence (up to 98%) by anti-fluorescein antibodies is well documented in the literature. Here we report a system where, instead of quenching, bifluorophoric molecules are designed to increase in fluorescence upon binding by an anti-fluorescein antibody. Bifluorophoric molecules are made of fluorescein (F) linked to tetramethylrhodamine (T) via varying numbers of methylene units, denoted as F-(CH(2))(n)-T. These F-(CH(2))(n)-T conjugates are almost nonfluorescent when free in solution due to intramolecular dimerization and stacking. Upon binding to an anti-fluorescein antibody, however, up to 110-fold increase in fluorescence was observed from the rhodamine moiety. This increase is believed to result from intramolecular dimer dissociation that dequenches the rhodamine fluorescence. Fluorescein fluorescence, on the other hand, remains quenched due to binding and intramolecular resonance energy transfer. Moreover, the excitation wavelength was at the absorption maxima of fluorescein, giving a Stoke's shift of about 90 nm. This system couples directly molecular recognition with a concurrent increase in fluorescence emission, obviating wash and incubation steps required by most assays. It is an important molecular reporter system for developing homogeneous assays.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jmr.593DOI Listing

Publication Analysis

Top Keywords

bifluorophoric molecules
12
increase fluorescence
12
binding anti-fluorescein
8
anti-fluorescein antibody
8
fluorescence
6
molecules fluorescent
4
fluorescent beacons
4
beacons antibody-antigen
4
binding
4
antibody-antigen binding
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!