There is an abundance of evidence indicating that the oral administration of sodium (13I)I-iodide is of value in the management of well-differentiated thyroid cancers. The first step in the management of thyroid cancer is near-total removal of the thyroid gland. Destroying any residual functioning thyroid tissue in the neck or metastatic tissue elsewhere in the body using (131)I after surgery decreases the risk of recurrence and death from well-differentiated thyroid cancers. The dosage of radioiodine used for this purpose varies among different centers. Until a few years ago, radioiodine therapy using >1.110 GBq (30 mCi) (131)I required hospitalization of patients to minimize radiation exposure to others. The U.S. Nuclear Regulatory Commission (USNRC) revised Title 10 of the Code of Federal Regulations (10CFR 35.75) in 1997, allowing the release of patients immediately after (131)I therapy if the total effective dose equivalent from the patient to an individual does not exceed 5 mSv (0.5 rem) in any 1 y. With this change, which became effective on May 29, 1997, a patient can be treated with a higher amount of (131)I as an outpatient and leave the premises with proper instructions to keep the radiation exposure to other individuals as low as it is reasonably achievable. The objectives of this article are to (a) briefly review the types of thyroid cancer; (b) provide an overall review of the treatment of thyroid carcinomas, follow-up of these patients, and the prognostic indicators of survival; and (c) explain the radiation safety precautions and the preventive measures that can be taken to minimize the radiation exposure of family members or helpers living with the patient and the general public at large.
Download full-text PDF |
Source |
---|
J Interv Card Electrophysiol
January 2025
Department of Cardiovascular Medicine, Dokkyo Medical University, 880 Kitakobayashi, Mibu, Shimotsugagun, Tochigi, 321-0293, Japan.
Background: The conventional mapping approach for the atrioventricular accessory pathway (AP) involves point-by-point mapping to identify the connection sites of the AP to the atria or ventricle and accurate interpretation of local electrograms. Omnipolar mapping technology (OMT) explains how vector and wave speed are produced by using both unipolar and bipolar signals to obtain omnipolar signals, directions, and conduction velocity. The aim of this study is to verify the effectiveness of OMT for catheter ablation of AP.
View Article and Find Full Text PDFRadiat Environ Biophys
January 2025
Department of Environmental Health Sciences, #820-11, Slot, Fay W. Boozman College of Public Health, University of Arkansas for Medical Sciences, 4301 W. Markham Str, Little Rock, AR, 72205, USA.
Most studies on the effects of galactic cosmic rays (GCR) have relied on terrestrial irradiation using spatially homogeneous dose distributions of mono-energetic beams comprised of one ion species. Here, we exposed mice to novel beams that more closely mimic GCR, namely, comprising poly-energetic ions of multiple species. Six-month-old male and female C57BL/6J mice were exposed to 0 Gy, 0.
View Article and Find Full Text PDFSci Prog
January 2025
National Fire Research Institute, Asan-si, Republic of Korea.
Firefighters are exposed to the risk of burns at fire scenes. In 2020, the National Fire Agency of the Republic of Korea surveyed 50,527 firefighters and identified 242 burn-related incidents. The body parts affected by these burns were the hands (28.
View Article and Find Full Text PDFCureus
December 2024
Department of Diagnostic Imaging and Radiotherapy, Kulliyyah of Allied Health Sciences, International Islamic University Malaysia, Kuantan Campus, Kuantan, MYS.
In abdominal X-ray examinations, radiosensitive organs such as the gonads within or near the imaging region are at risk of radiation exposure. Minimizing the dose to these organs is crucial to reducing unnecessary radiation. This study utilized optically stimulated luminescence dosimeters (OSLDs) to measure the radiation dose to the male gonads at varying kilovoltage peak (kVp) settings while keeping the milliampere-seconds (mAs) constant across different radiographic projections.
View Article and Find Full Text PDFJ Exp Orthop
January 2025
Department of Orthopedics and Traumatology, Knee Unit, Parc Taulí Hospital Universitari, Institut d'Investigació I Innovació Parc Taulí (I3PT-CERCA) Universitat Autònoma Barcelona (UAB) Sabadell Spain.
Purpose: Tibial valgus osteotomy has shown to be a successful and cost-effective procedure. The advent of image processing and three-dimensional (3D) printing is an interesting tool for achieving more accurate and reproducible results. The aim of our study was to compare the accuracy of the conventional technique and the use of customized guides in the correction of tibial deformities in tibial varus patients, the surgical and clinical benefits, and the impact of treatment in the outpatient setting.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!