In vivo CH3(CH2)11SAu SAM electrodes in the beating heart: in situ analytical studies relevant to pacemakers and interstitial biosensors.

Biosens Bioelectron

Departments of Pediatrics and Chemistry, University of Illinois, 840 South Wood St., M/C 856, Chicago, IL 60612, USA.

Published: January 2003

To study in vivo modification of the SAM equivalent circuit when a highly ordered SAM is used as a bioelectrode, dodecanethiolate SAM-Au intramuscular electrodes were studied in living rat heart in a challenging in situ perfused rat model by impedance spectroscopy, cyclic voltammetry, and neutron activation analysis (NAA). The SAM layer experienced disintegration in vivo biological system, as NAA detected the presence of Au atoms that had leached into the surrounding living tissue. Therefore, the underlying Au surface became exposed during biological implant. Study by impedance spectroscopy, however, revealed perfect capacitive behavior for the SAM, similar to in vitro behavior. Electrodes showed a pure capacitive Nyquist plot with 86.1-89.4 degrees near-vertical line segments as the equivalent circuit locus, as for a parallel plate capacitor. Impedance magnitude varied linearly with 1/omega excluding diffusionally limited ionic charge transport. There was no diffusional conductive element Z(W infinity ) or spatially confined Warburg impedance Z(D). The effect of in vivo exposure of a highly ordered SAM is a 'sealing over' effect of new defects by the binding of proteinaceous or lipid species in the biological milieu, a fact of significance for SAM electrodes used either as pacemaker electrodes or as a platform for in vivo biosensors.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0956-5663(02)00116-1DOI Listing

Publication Analysis

Top Keywords

sam electrodes
8
equivalent circuit
8
highly ordered
8
ordered sam
8
impedance spectroscopy
8
sam
7
vivo
5
electrodes
5
vivo ch3ch211sau
4
ch3ch211sau sam
4

Similar Publications

Impedimetric Biosensors for the Quantification of Serum Biomarkers for Early Detection of Lung Cancer.

Biosensors (Basel)

December 2024

Faculty of Engineering and Applied Sciences, Cranfield University, Cranfield, Bedfordshire MK43 0AL, UK.

Lung cancer is the most common type of cancer diagnosed worldwide and is also among the most fatal. Early detection, before symptoms become evident, is fundamental for patients' survival. Therefore, several lung cancer biomarkers have been proposed to enable a prompt diagnosis, including neuron-specific enolase (NSE) and carcinoembryonic antigen (CEA).

View Article and Find Full Text PDF

The high rate of cancer worldwide and the heavy costs imposed on governments and humanity have always motivated researchers to develop point-of-care (POC) biosensors for easy diagnosis and monitoring of cancer treatment. Herein, we report on a label-free impedimetric biosensor based on TiCT MXene and imprinted ortho-phenylenediamine (o-PD) for the detection of carcinoembryonic antigen (CEA), a biomarker for various cancers surveillance, especially colorectal cancer (CRC). Accordingly, MXene was drop-casted on the surface of a disposable silver electrode to increase the sensitivity and create high-energy nanoareas on the surface, which are usable for protein immobilization and detection.

View Article and Find Full Text PDF

The photovoltaic performance of inverted perovskite solar cells (PSCs) relies on effectively managing the interface between the hole extraction layer and the light-absorbing perovskite layer. In this study, we have synthesised (4-(3,6-bis(methylthio)-9H-carbazol-9-yl)butyl)phosphonic acid (MeS-4PACz), which forms a self-assembled monolayer on the fluorine-doped tin oxide (FTO) electrode. The molecule's methylthio substituents generate a favourable interfacial dipole moment and interact with the perovskite layer.

View Article and Find Full Text PDF

The significant contact resistance at the metal-semiconductor interface is a well-documented issue for organic thin-film transistors (OTFTs) that hinders device and circuit performance. Here, this issue is tackled by developing three new thiol carbazole-based self-assembled monolayer (SAM) molecules, namely tBu-2SCz, 2SCz, and Br-2SCz, and utilizing them as carrier-selective injection interlayers. The SAMs alter the work function of gold electrodes by more than 1 eV, making them suitable for use in hole and electron-transporting OTFTs.

View Article and Find Full Text PDF

An adaptive learning method for long-term gesture recognition based on surface electromyography.

Physiol Meas

December 2024

Fuzhou University, No.2 Xueyuan Road, Minhou County, Fuzhou City, Fujian Province, China., Fuzhou, Fujian, 350002, CHINA.

Article Synopsis
  • * To overcome these challenges, the authors propose a new method that involves optimizing feature extraction, dimensionality reduction, and model calibration to recognize EMG signals effectively over time.
  • * Their method, tested over 30 days of data, shows over 90% accuracy in gesture recognition using only one set of unlabeled samples, demonstrating both high performance and convenience for daily use.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!