AI Article Synopsis

Article Abstract

Neutron measurement results obtained at SINP MSU since 1970 are presented. These measurements were made using techniques based on neutron moderation and subsequent detection in a Li6I(Eu) crystal or a He3 coronal counter. The measurements were mainly carried out in orbits with inclination of 52 degrees and altitudes of 200-450 km. The spatial and angular distributions of the measured neutron fluxes were studied. The albedo neutron flux was estimated according to the count rate difference for opposite detector orientations towards Earth and away from it. This flux is comparable to the local neutron flux outside the Brazil anomaly region, where local neutrons dominate. Neutron fluxes, generated by solar protons, were detected during a solar flare on June 6, 1991 for the first time. Their spectrum was estimated as a power law with alpha>2.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s1350-4487(02)00086-0DOI Listing

Publication Analysis

Top Keywords

neutron fluxes
12
neutron flux
8
neutron
6
measurements neutron
4
fluxes energies
4
energies thermal
4
thermal mev
4
mev near-earth
4
near-earth space
4
space sinp
4

Similar Publications

Dose optimization of extended collimators in boron neutron capture therapy.

Biomed Phys Eng Express

December 2024

Shandong Key Laboratory of Neutron Science and Technology, International Academy of Neutron Science, Qingdao 266199, People's Republic of China.

In this paper, we propose the design of extending collimators aimed at reducing the radiation dose received by patients with normal tissues and protecting organs at risk in Boron Neutron Capture Therapy (BNCT). Three types of extended collimators are studied: Type 1, which is a traditional design; Type 2, which is built upon Type 1 by incorporating additional polyethylene material containing lithium fluoride (PE(LiF)); Type 3, which adds lead (Pb) to Type 1. We evaluated the dose distribution characteristics of the above-extended collimators using Monte Carlo methods simulations under different configurations: in air, in a homogeneous phantom, and a humanoid phantom model.

View Article and Find Full Text PDF
Article Synopsis
  • Active neutron interrogation (ANI) is crucial for detecting special nuclear materials (SNMs), but matrix materials can reduce the accuracy of fissile mass measurements.
  • A new matrix correction method utilizes neutron flux monitor group (NFMG) responses to quantify and manage these matrix effects, even for unknown matrices.
  • Validation using the Geant4 toolkit shows that the improved simulated annealing algorithm can accurately identify matrix types and correct the measurement of uranium mass, maintaining deviations within acceptable ranges.
View Article and Find Full Text PDF

Neutron detection is nowadays mostly based on He gas detectors, but its shortage and the continuous upgrades of the neutron facilities require new devices to perform experiments with maximum performances. This work presents a new detector based on the Gas Electron Multiplier (GEM) combined with several boron layers. This detector combines the features of GEM technology with the properties of boron as a neutron converter and the device is produced to sustain high neutron fluxes with high detection efficiency.

View Article and Find Full Text PDF

From the viewpoints of the advantage depths (ADs), peak tumor dose and skin dose, we evaluated the effect on the dose distribution of neutron beam properties, namely the ratio between thermal and epithermal neutron fluxes (thermal/epithermal ratio), fast neutron component and γ-ray component. Several parameter surveys were conducted with respect to the beam properties of neutron sources for boron neutron capture therapy assuming boronophenylalanine as the boron agent using our dose calculation tool, called SiDE. The ADs decreased by 3% at a thermal/epithermal ratio of 20-30% compared with the current recommendation of 5%.

View Article and Find Full Text PDF

Development of a thermal diagnostic system for the SPARC tokamak.

Rev Sci Instrum

October 2024

Commonwealth Fusion Systems, Devens, Massachusetts 01434, USA.

Article Synopsis
  • The SPARC tokamak is a fusion reactor that will get very hot, so it's important to manage the heat to keep everything safe.
  • To do this, they will use special tools called thermal diagnostics to measure the temperatures inside the reactor and make sure they don't get too high.
  • Different types of sensors will be used, and they are designed to survive extreme conditions, including super high temperatures and radiation, since fixing them later will be really hard.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!