Objective: To document the long-term surgical and audiologic results of the implantation of a first-generation semi-implantable hearing aid for mixed hearing loss, consisting of a magnetic partial or total ossicular replacement prosthesis and an electromagnetic driver fitted in the ear canal. The short-term results have previously been published as excellent in both surgical and audiologic terms. To analyze and discuss reasons of treatment failure, as well as future perspectives.

Study Design: Patient file review, follow-up otomicroscopic examination and audiometry, as well as patient interview. SETTING Tertiary referral center at a University hospital.

Patients: Of nine patients operated on, six with a mixed hearing loss after chronic otitis media could be evaluated primarily. Two underwent implantation with a partial and four with a total ossicular replacement prosthesis.

Main Outcome Measures: Use of and satisfaction with the hearing aid, apparatus function and integrity, hearing without electromagnetic driver, prostheses containment, drum abnormalities, nonaudiologic ear symptoms, e.g., discharge.

Results: All patients attended follow-up for a mean of 9.5 years after implantation (range 8.8-10 years). No patients used the semi-implantable hearing aid at follow-up. The mean semi-implantable hearing aid using time was 24 months (range 3-60 months). The main reasons for discontinuation of use were problems fitting the electromagnetic driver correctly in the ear canal and prosthesis extrusion or dislocation.

Conclusions: Despite excellent short-term surgical and audiologic results, it is concluded that these first long-term results of the first-generation electromagnetic semi-implantable hearing aids with ossicular replacement prosthesis for mixed hearing loss are disappointing. However, improvements in the surgical approach and in the reshaping, refinement, and overall improvement of the semi-implantable hearing aid could lead to satisfactory treatment of this group of patients.

Download full-text PDF

Source
http://dx.doi.org/10.1097/00129492-200211000-00016DOI Listing

Publication Analysis

Top Keywords

hearing aid
24
semi-implantable hearing
20
ossicular replacement
16
mixed hearing
16
hearing loss
16
hearing
12
surgical audiologic
12
electromagnetic driver
12
first-generation semi-implantable
8
partial total
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!