A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Detection and characterization of intracardiac thrombi on MR imaging. | LitMetric

Detection and characterization of intracardiac thrombi on MR imaging.

AJR Am J Roentgenol

Department of Diagnostic and Interventional Radiology, University Hospital Essen, Hufelandstrasse 55, D-45122 Essen, Germany.

Published: December 2002

Objective: The aim of our study was to compare the diagnostic accuracy achieved using different MR techniques with the diagnostic accuracy achieved using transthoracic and transesophageal echocardiography to detect intracardiac thrombi.

Materials And Methods: Twenty-four patients with known or suspected intracardiac thrombi were examined using MR imaging and echocardiography. All MR examinations were performed on a 1.5-T MR scanner using dark-blood-prepared half-Fourier acquisition single-shot turbo spin-echo (HASTE) sequences, fast imaging steady-state free precession (trueFISP) cine sequences, and inversion recovery gradient-echo fast low-angle-shot (inversion recovery turbo FLASH) sequences after injection of 0.2 mmol/kg of gadolinium diethylene triamine pentaacetic acid.

Results: MR imaging and echocardiography revealed 12 thrombi-two in the right atrium, one in the right ventricle, three in the left atrium, and six in the left ventricle. Compared with echocardiography, MR imaging revealed three additional thrombi in the left ventricle; these thrombi were confirmed at surgery. All 15 thrombi appeared as filling defects on early contrast-enhanced inversion recovery turbo FLASH MR images. Only seven thrombi were detected on HASTE images, and 10 thrombi were seen on trueFISP images. Four thrombi showed enhancement 10-20 min after contrast material injection and were characterized as organized clots.

Conclusion: Contrast-enhanced inversion recovery turbo FLASH sequences were superior to dark-blood-prepared HASTE and trueFISP cine MR images in revealing intracardiac thrombi. Compared with transthoracic echocardiography, MR imaging was more sensitive for the detection of left ventricular thrombi. The characterization of thrombi may be used to predict the risk of embolism, which is higher for subacute clots than for organized thrombi.

Download full-text PDF

Source
http://dx.doi.org/10.2214/ajr.179.6.1791539DOI Listing

Publication Analysis

Top Keywords

inversion recovery
16
thrombi
12
intracardiac thrombi
12
recovery turbo
12
turbo flash
12
images thrombi
12
diagnostic accuracy
8
accuracy achieved
8
imaging echocardiography
8
truefisp cine
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!