Metabonomic analysis of biofluids and tissues utilizing high-resolution NMR spectroscopy and chemometric techniques has proven valuable in characterizing the biochemical response to toxicity for many xenobiotics. To assess the analytical reproducibility of metabonomic protocols, sample preparation and NMR data acquisition were performed at two sites (one using a 500 MHz and the other using a 600 MHz system) using two identical (split) sets of urine samples from an 8-day acute study of hydrazine toxicity in the rat. Despite the difference in spectrometer operating frequency, both datasets were extremely similar when analyzed using principal components analysis (PCA) and gave near-identical descriptions of the metabolic responses to hydrazine treatment. The main consistent difference between the datasets was related to the efficiency of water resonance suppression in the spectra. In a 4-PC model of both datasets combined, describing all systematic dose- and time-related variation (88% of the total variation), differences between the two datasets accounted for only 3% of the total modeled variance compared to ca. 15% for normal physiological (pre-dose) variation. Furthermore, <3% of spectra displayed distinct inter-site differences, and these were clearly identified as outliers in their respective dose-group PCA models. No samples produced clear outliers in both datasets, suggesting that the outliers observed did not reflect an unusual sample composition, but rather sporadic differences in sample preparation leading to, for example, very dilute samples. Estimations of the relative concentrations of citrate, hippurate, and taurine were in >95% correlation (r(2)) between sites, with an analytical error comparable to normal physiological variation in concentration (4-8%). The excellent analytical reproducibility and robustness of metabonomic techniques demonstrated here are highly competitive compared to the best proteomic analyses and are in significant contrast to genomic microarray platforms, both of which are complementary techniques for predictive and mechanistic toxicology. These results have implications for the quantitative interpretation of metabonomic data, and the establishment of quality control criteria for both regulatory agencies and for integrating data obtained at different sites.

Download full-text PDF

Source
http://dx.doi.org/10.1021/tx0255774DOI Listing

Publication Analysis

Top Keywords

analytical reproducibility
12
normal physiological
8
metabonomic
5
analytical
4
reproducibility nmr-based
4
nmr-based metabonomic
4
metabonomic urinalysis
4
urinalysis metabonomic
4
metabonomic analysis
4
analysis biofluids
4

Similar Publications

Background: INTER- and INTRAmuscular fat (IMF) is elevated in high metabolic states and can promote inflammation. While magnetic resonance imaging (MRI) excels in depicting IMF, the lack of reproducible tools prevents the ability to measure change and track intervention success.

Methods: We detail an open-source fully-automated iterative threshold-seeking algorithm (ITSA) for segmenting IMF from T1-weighted MRI of the calf and thigh within three cohorts (CaMos Hamilton (N = 54), AMBERS (N = 280), OAI (N = 105)) selecting adults 45-85 years of age.

View Article and Find Full Text PDF

In this study, DL-phenylalanine modified with a multiwall carbon nanotube paste electrode is used as advanced electrochemical sensor for analysing of 0.1 mM caffeic acid (CFA) with simultaneous detection of riboflavin (RFN). The developed sensors include electrochemically polymerized DL-phenylalanine (DL-PA) modified multiwall carbon nanotube paste electrode [DL-PAMMCNTPE] and bare multiwall carbon nanotube paste electrode [BMCNTPE].

View Article and Find Full Text PDF

An efficient modified QuEChERS procedure was established for the simultaneous determination of 37 pesticide residues in fresh and processed edible button mushroom by employing GC/ GC-MS and LC-MS/MS. The effectiveness, reliability and accuracy of the method were assessed through validation parameters such as linearity, LOD, LOQ, precision, accuracy, uncertainty, and matrix effect. The linearity calibration for all the selected pesticides at standard concentrations (0.

View Article and Find Full Text PDF

Background: Serology for dengue viruses (DENV) and Zika virus (ZIKV) has been hindered by antibody cross-reactivity, which limits the utility of these tests for surveillance and assessment of sero-status. Our aim was to develop a multiplexed IgG-based assay with increased accuracy to assess the history of previous DENV and ZIKV infections.

Methods: We developed and assessed the analytical performance of a sample-sparing, multiplexed, microsphere-based serological assay using domain III of the envelope protein (EDIII) of DENV serotypes 1-4 and ZIKV, the most variable region between each virus.

View Article and Find Full Text PDF

Aflatoxin M1 (AFM1) exposure through dairy products is associated with adverse health effects, including hepatotoxicity and carcinogenicity. Therefore, the AFM1 presence in milk and dairy products is strictly regulated. In this context, the current work focuses on the investigation of different competitive enzyme immunoassay configurations for the determination of AFM1 in milk with high sensitivity and short assay duration.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!