AI Article Synopsis

Article Abstract

Wave intensity (WI) is a new hemodynamic index that provides information about the dynamic behavior of the heart and the vascular system and their interaction. Carotid arterial wave intensity in normal subjects has two positive peaks. The first peak, W(1), occurs during early systole, the magnitude of which increases with increases in cardiac contractility. The second peak, W(2), which occurs towards the end of ejection, is related to the ability of the left ventricle to actively stop aortic blood flow. Between the two positive peaks, a negative area, NA, is often observed, which signifies reflections from the cerebral circulation. The time interval between the R-wave of ECG and the first peak (R - W(1)) corresponds to the pre-ejection period, and that between the first and second peaks (W(1) - W(2)) corresponds to ejection time. We developed a new ultrasonic on-line system for obtaining WI and arterial stiffness (beta). The purpose of this study was (1) to report normal values of various indices derived from WI and beta measured with this system, and (2) to evaluate the intraobserver and interobserver reproducibility of the measurements. The measurement system is composed of a computer, a WI unit, and an ultrasonic machine. The WI unit gives the instantaneous change in diameter of the artery and the instantaneous mean blood velocity through the sampling gate. Using these parameters and blood pressure measured with a cuff-type manometer, the computer gives WI and beta. We applied this method to the carotid artery in 135 normal subjects. The mean values of W(1), W(2), NA, R - W(1), and W(1) - W(2) were 8 940 +/- 3 790 mmHg m/s(3), 1 840 +/- 880 mmHg m/s(3), 27 +/- 13 mmHg m/s(2), 104 +/- 14 ms, and 270 +/- 19 ms, respectively. These values did not show a significant correlation with age. The mean value of beta was 10.4 +/- 4.8 and the values significantly correlated with age (men: r = 0.66, P < 0.0001; women: r= 0.81, P < 0.0001). The reproducibility was evaluated by intraobserver intrasession (IA), intraobserver intersession (IE), and interobserver intrasession variability (IO). The reproducibility of R - W(1) and W(1) - W(2) was high: the mean coefficient of variation (mCV) of IA was less than 3%; 95% confidence limits from the mean values (CL) were less than 8% for IE and less than 4% for IO. The reproducibility of W(1) and beta was good: mCV for IA was less than 10%; CL for IE and IO were less than 17%. W(2) and NA showed a higher variability than other indices: mCV for IA was less than 13%, and CL for IE and IO were less than 36%. However, two sessions by the same observer and two sessions by different observers were not biased. Wave intensity measurements with this system are clinically acceptable.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s003800200037DOI Listing

Publication Analysis

Top Keywords

wave intensity
20
measurement system
8
carotid arterial
8
arterial wave
8
normal subjects
8
positive peaks
8
peak occurs
8
mmhg m/s3
8
104 +/-
8
+/- values
8

Similar Publications

The development of diverse microstructures has substantially contributed to recent progress in high-performance electromagnetic wave (EMW) absorption materials, providing a versatile platform for the modulation of absorption properties. Exploring multidimensional microstructures and developing tailored and gentle strategies for their precise optimization can substantially address the current challenges posed by relatively unclear underlying mechanisms. Here, a series of 2D/1D heterogeneous NiO@PPy composites featuring hollow hierarchical microstructures are successfully synthesized using a straightforward strategy combining sacrificial templating with chemical oxidative polymerization.

View Article and Find Full Text PDF

Paddlewheel-type and half-paddlewheel-type diruthenium(II,II) complexes with 1,8-naphthyridine-2-carboxylate.

Dalton Trans

January 2025

Department of Chemistry, Graduate School of Natural Science and Technology, Shimane University, 1060, Nishikawatsu, Matsue, Shimane, 690-8504, Japan.

Paddlewheel-type diruthenium(II,II) complexes are paramagnetic with two unpaired electrons ( = 1) and can be utilized as versatile building blocks for higher-order structures, such as supramolecular complexes, coordination polymers, and metal-organic frameworks, although they are generally highly air-sensitive. In this study, we developed an air-stable paddlewheel-type diruthenium(II,II) complex with two electron-withdrawing 1,8-naphthyridine-2-carboxylate (npc) ligands, [Ru(μ-npc)(OCMe)] (1). The two acetate ligands in 1 can be replaced by other carboxylate ligands; the solvothermal reactions of 1 with benzoic acid (HOCPh) yields the heteroleptic [Ru(μ-npc)(OCPh)] (2), whereas its reaction with 1,8-naphthyridine-2-carboxylic acid (Hnpc) produces the homoleptic [Ru(μ-npc)(η-npc)] (3).

View Article and Find Full Text PDF

In this study, we investigated in detail the regulation mechanism of electron transfer under laser-induced breakdown (LIB) on weak O-D stimulated Raman scattering (SRS) in DMSO-DO solutions. Significantly, the Raman activity of O-D vibrations was greatly enhanced by two orders of magnitude due to electron transfer in DMSO molecules. Density functional theory (DFT) calculations showed that the O-D Raman activity was significantly enhanced in the DMSO-DO dimer compared to the DO dimer.

View Article and Find Full Text PDF

Complete 2π cycling of a phase around a phase singularity leads to a rapid phase variation in the nearby zones and forms a sharp local -vector peak. In this paper, the intensity distribution in the spatial domain is transformed into a -vector distribution in the wave vector domain, and we prove that the local -vector peak is generated at the point of minimum light field intensity. The local -vector peak is sharper when the minimum point is closer to the phase singularity.

View Article and Find Full Text PDF

Metasurfaces have exhibited excellent capabilities in controlling main characteristics of electromagnetic fields. Thus, a lot of significant achievements have been attained in many areas especially in the fields of hologram and near-field imaging. However, some of these designs are implemented in a manner of interleaved subarrays that complicates the design and makes them difficult to achieve integration.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!