Prototyping disposable electrophoresis microchips with electrochemical detection using rapid marker masking and laminar flow etching.

Electrophoresis

Pennsylvania State University, Department of Chemistry, University Park, PA 16802, USA.

Published: November 2002

Two novel methods are described for the fabrication of components for microchip capillary electrophoresis with electrochemical detection (microchip CEEC) on glass substrates. First, rapid marker masking is introduced as a completely nonphotolithographic method of patterning and fabricating integrated thin-film metal electrodes onto a glass substrate. The process involves applying the pattern directly onto the metal layer with a permanent marker that masks the ensuing chemical etch. The method is characterized, and the performance of the resulting electrode is evaluated using catecholamines. The response compares well with photolithographically defined electrodes and exhibits detection limits of 648 nM and 1.02 microM for dopamine and catechol, respectively. Second, laminar flow etching is introduced as a partially nonphotolithographic method of replicating channel networks onto glass substrates. The replication process involves applying a poly(dimethylsiloxane) (PDMS) mold of the channel network onto a slide coated with a sacrificial metal layer and then pulling solutions of metal etchants through the channels to transfer the pattern onto the sacrificial layer. The method is tested, and prototype channel networks are shown. These methods serve to overcome the time and cost involved in fabricating glass-based microchips, thereby making the goal of a disposable high performance lab-on-a-chip more attainable.

Download full-text PDF

Source
http://dx.doi.org/10.1002/1522-2683(200211)23:21<3735::AID-ELPS3735>3.0.CO;2-7DOI Listing

Publication Analysis

Top Keywords

electrochemical detection
8
rapid marker
8
marker masking
8
laminar flow
8
flow etching
8
glass substrates
8
nonphotolithographic method
8
process involves
8
involves applying
8
metal layer
8

Similar Publications

Polycyclic aromatic hydrocarbons (PAHs) are carcinogenic compounds resulting from incomplete burning of organic materials. This work describes the successful layer-by-layer fabrication of a novel zinc oxide nanocomposite made of zinc oxide nanoparticles, aniline, sodium dodecyl sulfate, and modified multi-walled carbon nanotubes on a stainless steel wire by electrodeposition. The coating and extraction conditions were screened, optimized, and validated using factorial design and central composite design, respectively.

View Article and Find Full Text PDF

The trace detection of pyocyanin (PCN) is crucial for infection control, and electrochemical sensing technology holds strong potential for application in this field. A pivotal challenge in utilizing carbon materials within electrochemical sensors lies in constructing carbon-based films with robust adhesion. To address this issue, a novel composite hydrogel consisting of multi-walled carbon nanotubes/polyvinyl alcohol/phosphotungstic acid (MWCNTs/PVA/PTA) was proposed in this study, resulting in the preparation of a highly sensitive and stable PCN electrochemical sensor.

View Article and Find Full Text PDF

Reusable Biosensor for Easy RNA Detection from Unfiltered Saliva.

Sensors (Basel)

January 2025

Department of Clinical and Molecular Biochemistry, Pomeranian Medical University in Szczecin, 72 Powstańców Wlkp. Al., 70-111 Szczecin, Poland.

Biosensors are transforming point-of-care diagnostics by simplifying the detection process and enabling rapid, accurate testing. This study introduces a novel, reusable biosensor designed for direct viral RNA detection from unfiltered saliva, targeting SARS-CoV-2. Unlike conventional methods requiring filtration, our biosensor leverages a unique electrode design that prevents interference from saliva debris, allowing precise measurements.

View Article and Find Full Text PDF

Elevated dopamine (DA) levels in urine denote neuroblastoma, a pediatric cancer. Saccharide-derived carbon dots (CDs) were applied to assay DA detection in simulated urine (SU) while delineating the effects of graphene defect density on electrocatalytic activity. CDs were hydrothermally synthesized to vary graphene defect densities using sucrose, raffinose, and palatinose, depositing them onto glassy carbon electrodes (GCEs).

View Article and Find Full Text PDF

This paper summarizes the main findings of a study which aimed to examine the electrochemical oxidation of homovanillic acid (HVA), the final metabolite of dopamine. A pencil graphite electrode (PGE) was used as working electrode and the measurements were performed by cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The type and the composition of the graphite leads used as PGE, the pH of the supporting electrolyte, as well as the scan rates were optimized by CV.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!