Measurement of left ventricular (LV) function is often overlooked in murine studies, which have been used to analyze the effects of genetic manipulation on cardiac phenotype. The goal of this study was to address the effects of changes in LV contractility on indexes of contractility in mice. LV function was assessed in vivo in closed-chest mice by echocardiography and by LV catheterization using a conductance pressure-volume (P-V) catheter with three different interventions that alter contractility by 1) atrial pacing to increase inotropy by augmentation of the force-frequency relation (modest increment of inotropy), 2) dobutamine to maximize inotropy, and 3) esmolol infusion to decrease contractility. Load-independent parameters derived from P-V relations, such as slope of end-systolic P-V relations (ESPVR) and slope of the first maximal pressure derivative over time (dP/dt(max))-end-diastolic volume relation (dP/dt-EDV), and standard echocardiographic parameters were measured. The dP/dt-EDV changed the most among parameters after atrial pacing and dobutamine infusion (percent change, 162.8 +/- 95.9% and 271.0 +/- 44.0%, respectively). ESPVR was the most affected by a decrease in LV contractility during esmolol infusion (percent change, -49.8 +/- 8.3%). However, fractional shortening failed to detect changes in contractility during atrial pacing and esmolol infusion and its percent change was <20%. This study demonstrated that contractile parameters derived from P-V relations change the most during a change in LV contractility and should therefore best detect a small change in contractility in mice. Heart rate has a modest but significant effect on P-V relationship-derived indexes and must be considered in the evaluation of murine cardiac physiology.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1152/ajpheart.0765.2001 | DOI Listing |
Eur Heart J Case Rep
January 2025
Echocardiography Department, Great Ormond Street Hospital for Children, Great Ormond Street, London WC1N 3JH, UK.
Background: Superior caval vein obstruction is a rare complication of endocardial pacing lead implantation that can result in a right to left shunt.
Case Summary: A 3-year-old child with type 2 Brugada syndrome presented with mild cyanosis post-endocardial pacing implantation due to evolutionary right superior caval vein obstruction. This obstruction resulted in a right to left shunt across a previously unrecognized patent levo-atrial cardinal vein associated with partial anomalous pulmonary venous drainage.
Pacing Clin Electrophysiol
January 2025
Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Sapporo, Japan.
Background: This study aimed to compare inappropriate shock (IAS) rates between subcutaneous implantable cardioverter-defibrillator (S-ICD) and transvenous ICD (TV-ICD) in Brugada syndrome (BrS) patients and identify risk factors for IAS in S-ICD use.
Methods: We enrolled consecutive patients with BrS who underwent ICD implantation between 2013 and 2023. Data on clinical characteristics, S-ICD screening test data, and IAS occurrence were retrospectively analyzed.
Pacing Clin Electrophysiol
January 2025
Boston Scientific, Corporation: Electrophysiology Research & Development, Arden Hills, Minnesota, USA.
As pulsed-field ablation (PFA) emerges as a promising therapy for atrial arrhythmias, an understanding of the cellular injury to cardiac tissue is critical to evaluating and interpreting results for each PFA system. This review aims to detail the mechanism of cell death for PFA, compare the cell death mechanism to thermal ablation modalities, clarify common histology markers, detail the progression of PFA lesions from the acute, to subacute, to chronic maturation states, and discuss clinical indicators of PFA lesions.
View Article and Find Full Text PDFPacing Clin Electrophysiol
January 2025
Department of Cardiology, Saitama Medical University, International Medical Center, Hidaka, Saitama, Japan.
Background: The IntellaNav MiFi OI catheter (MiFi) is equipped with a sensor for local impedance (LI) monitoring and three mini-electrodes. In this study, we investigated the target LI values for a successful pulmonary vein isolation (PVI) under the pacing and ablation technique using the MiFi catheter.
Methods: Twenty-seven patients underwent PVI using the MiFi catheter under mini electrode pacing from the MiFi catheter.
Pacing Clin Electrophysiol
January 2025
Aurora Cardiovascular and Thoracic Services, Aurora Sinai/Aurora St. Luke's Medical Centers, Milwaukee, Wisconsin, USA.
Background: Concurrent Micra leadless pacemaker (Medtronic, Minneapolis, Minnesota) implantation and atrioventricular node (AVN) ablation has been shown to be feasible and safe in patients with symptomatic, drug-refractory atrial fibrillation (AF). However, major complications within the 30 days after concurrent Micra implantation and AVN ablation have been reported. We evaluated the efficacy and safety of the concurrent procedure at our institution.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!