Download full-text PDF

Source

Publication Analysis

Top Keywords

correct weight
4
weight aged?]
4
correct
1
aged?]
1

Similar Publications

Simultaneous multislice diffusion imaging using navigator-free multishot spiral acquisitions.

Magn Reson Med

January 2025

Center for Biomedical Imaging Research, School of Biomedical Engineering, Tsinghua University, Beijing, China.

Purpose: This work aims to raise a novel design for navigator-free multiband (MB) multishot uniform-density spiral (UDS) acquisition and reconstruction, and to demonstrate its utility for high-efficiency, high-resolution diffusion imaging.

Theory And Methods: Our design focuses on the acquisition and reconstruction of navigator-free MB multishot UDS diffusion imaging. For acquisition, radiofrequency-pulse encoding was used to achieve controlled aliasing in parallel imaging in MB imaging.

View Article and Find Full Text PDF

Motion-Compensated Multishot Pancreatic Diffusion-Weighted Imaging With Deep Learning-Based Denoising.

Invest Radiol

January 2025

From the Department of Radiology, Stanford University, Stanford, CA (K.W., M.J.M., A.M.L., A.B.S., A.J.H., D.B.E., R.L.B.); Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, CA (K.W.); GE HealthCare, Houston, TX (X.W.); GE HealthCare, Boston, MA (A.G.); and GE HealthCare, Menlo Park, CA (P.L.).

Objectives: Pancreatic diffusion-weighted imaging (DWI) has numerous clinical applications, but conventional single-shot methods suffer from off resonance-induced artifacts like distortion and blurring while cardiovascular motion-induced phase inconsistency leads to quantitative errors and signal loss, limiting its utility. Multishot DWI (msDWI) offers reduced image distortion and blurring relative to single-shot methods but increases sensitivity to motion artifacts. Motion-compensated diffusion-encoding gradients (MCGs) reduce motion artifacts and could improve motion robustness of msDWI but come with the cost of extended echo time, further reducing signal.

View Article and Find Full Text PDF

Purpose: Prior work estimating sound exposure dose from earphone use has typically measured earphone use time with retrospective questionnaires or device-based tracking, both of which have limitations. This research note presents an exploratory analysis of sound exposure dose from earphone use among college-aged adults using real-ear measures to estimate exposure level and ecological momentary assessment (EMA) to estimate use time.

Method: Earphone levels were measured at the ear drum of 53 college students using their own devices, earphones, and preferred music and speech stimuli at their normal listening volume.

View Article and Find Full Text PDF

Objective: To evaluate the effect of age correction up to 36 months of age for growth assessments of extremely preterm (<28 weeks) and very preterm (28 to <32 weeks) infants.

Study Design: This longitudinal analysis used data from the Preterm Infant Multicenter Growth Study (2001-2014).

Results: 1,416 children were included (Median gestational age = 27 weeks).

View Article and Find Full Text PDF

Genome-wide association studies (GWAS) are often performed on ratios composed of a numerator trait divided by a denominator trait. Examples include body mass index (BMI) and the waist-to-hip ratio, among many others. Explicitly or implicitly, the goal of forming the ratio is typically to adjust for an association between the numerator and denominator.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!