A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

PVC tracheal tubes exert forces and pressures seven to ten times higher than silicone or armoured tracheal tubes--an in vitro study. | LitMetric

PVC tracheal tubes exert forces and pressures seven to ten times higher than silicone or armoured tracheal tubes--an in vitro study.

Can J Anaesth

Departments of Anaesthesia, St. Michael's Hospital and the University Health Network, University of Toronto, Toronto, Ontario, Canada.

Published: November 2002

Purpose: Many types of tracheal tubes (TT) including silicone, polyvinylchloride (PVC) and armoured have been used for blind tracheal intubation (TI) via the intubating laryngeal mask airway (ILMA) and may cause trauma to the airway. We examined the maximal in vitro forces and pressures exerted by the tip of various TT as it exits the ILMA.

Methods: Silicone, PVC and armoured TT were studied. A #5 ILMA was secured on a wooden platform. With the use of a Harvard pump, force was applied to push the TT through the ILMA at 0.34 cm*sec(-1). Forces exerted to push the TT and forces exerted by the TT tips on distal objects were calculated using proximal and distal pressure manometres. The areas of contact between the distal TT tips and the distal objects were measured by planimetry of an imprint. The final pressures exerted by the TT tips on a fixed distal object were calculated by dividing the forces exerted by the areas of contact.

Results: When compared to silicone and armoured TT, PVC TT exerted seven to ten times higher forces and pressures on distal objects. (P < 0.05). Heating PVC TT and inserting PVC TT with reverse curvature to the ILMA did not decrease the forces and pressures exerted by the distal tip.

Conclusion: The high forces and pressures exerted by PVC TT may theoretically contribute to increased morbidity to patients' airway and esophagus. Caution should be exercised before attempting blind TI via the ILMA with a PVC TT.

Download full-text PDF

Source
http://dx.doi.org/10.1007/BF03016888DOI Listing

Publication Analysis

Top Keywords

forces pressures
20
pressures exerted
16
forces exerted
12
distal objects
12
pvc
8
tracheal tubes
8
forces
8
ten times
8
times higher
8
silicone armoured
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!