Objective: To compare bispectral index (BIS) values to hemodynamic variations, in order to evaluate adequacy of anesthesia during orotracheal intubation with muscle relaxants.
Methods: Forty-one patients ASA I-II, scheduled for elective peripheral surgery under general anesthesia with tracheal intubation were enrolled in the study. Fentanyl/thiopental followed by vecuronium were used for induction. Onset of relaxation was monitored at the orbicularis occuli (OO) muscle using train-of-four stimulation. Intubation was performed when no response at the OO was detected visually. Intubating conditions were noted. The "isolated forearm" technique was used to detect movement during laryngoscopy/intubation. BIS values, pulse rate (PR), and systolic pressure were recorded before induction, during laryngoscopy/intubation and 60 sec after intubation.
Results: Although intubating conditions were clinically adequate for all patients, ten out of 41 had movement of the isolated arm during laryngoscopy/intubation. BIS values were not significantly different for these patients: 67 (55-83) compared to those who had no movement: 60 (35-80), P = 0.6. During laryngoscopy, PR increased for all patients while systolic pressure increased significantly only in patients who moved: 125 (100-136) mmHg vs those who did not: 108 (67-140), P < 0.05.
Conclusion: Systolic pressure elevations were associated with inadequate anesthesia as evaluated by the "isolated forearm" technique, during laryngoscopy/intubation. BIS values were not different between groups, suggesting that systolic blood pressure may be a better predictor of inadequate anesthesia under the circumstances described.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/BF03016874 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!