A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Dosimetric comparison between high-precision external beam radiotherapy and endovascular brachytherapy for coronary artery in-stent restenosis. | LitMetric

Purpose: Several drawbacks of endovascular brachytherapy for the treatment of coronary artery in-stent restenosis may be addressed by high-precision external beam radiotherapy (EBRT). The dosimetric characteristics of both treatment techniques were compared.

Methods And Materials: The traversed volume of 10 coronary artery stents during the cardiac cycle was determined by electrocardiographically gated multislice spiral CT in 10 patients. By use of this traversed volume, high-precision EBRT treatment plans were generated for stents in the left circumflex (LCx), left anterior descending (LAD), and right coronary artery (RCA). The maximum dose to the nontargeted major coronary arteries was determined and compared to similar data calculated for endovascular brachytherapy.

Results: High-precision EBRT targeted at LCx stents contributed a mean maximum dose (D(max)) of 83.5% (range: 71.6-95.3%) and 16.3% to the LAD and RCA, respectively. Targeted LAD stents contributed a mean D(max) of 39.3% (range: 14.5-94.8%) and 5.2% (range: 0-13.4%) to the LCx and RCA, respectively. Targeted RCA stents contributed a mean D(max) of 6.2% (range: 0-12.4%) and 5.8% (range: 0-11.5%) to the LCx and LAD, respectively. Endovascular brachytherapy targeted at LCx stents contributed a mean D(max) of 1.7% (range: 0.7-2.7%) and 1.0% (range: 0.6-1.4%) to the LAD and RCA, respectively. Targeted LAD stents contributed a mean D(max) of 5.2% (range: 0.5-11.4%) and 0.7% (range: 0.4-1.1%) to the LCx and RCA, respectively; targeted RCA stents contributed a mean D(max) of 0.3% (range: 0.2-0.5%) and 0.2% (range: 0.1-0.3%) to the LCx and LAD, respectively.

Conclusions: Although the doses distributed throughout the heart were higher for high-precision EBRT compared to endovascular brachytherapy, they are expected to be clinically irrelevant when nontargeted major coronary arteries are not closely situated to the targeted vessel segment. These encouraging results warrant further investigation of high-precision EBRT as a potential alternative to endovascular brachytherapy for the treatment of coronary artery in-stent restenosis.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0360-3016(02)03020-1DOI Listing

Publication Analysis

Top Keywords

stents contributed
24
endovascular brachytherapy
20
coronary artery
20
contributed dmax
20
high-precision ebrt
16
rca targeted
16
artery in-stent
12
in-stent restenosis
12
range
11
high-precision external
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!