A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Influence of mandibular protruding device on airway passages and dentofacial characteristics in obstructive sleep apnea and snoring. | LitMetric

The aim of the study was to evaluate the influence of a mandibular protruding device (MPD) after 2 years of nocturnal use on the upper airway and its surrounding structures. Lateral cephalograms in the upright position were taken of patients with obstructive sleep apnea (OSA) and of patients with snoring problems at the beginning of treatment and at the 2-year follow-up. Two computer programs were used to analyze the cephalograms. A total of 65 patients, 44 with OSA and 21 snorers, were analyzed. The linear distances in the pharynx had increased significantly at the 2-year follow-up; the calculated pharyngeal area had increased on average by 9% (mean, +58.3 mm(2)). The velum area had decreased (mean, -31.5 mm(2)), which accounts for about half the increase in the relative area of the pharynx. The average linear distances between the hyoid bone and the 2 reference lines, ie, nasal line (NL) and mandibular line (ML), had increased significantly. Mandibular protrusion (SNB) was slightly reduced, on average -0.4 degrees (P <.01), and the lower incisors were proclined (ILi/ML), on average +1.5 degrees (P <.05). In conclusion, nocturnal use of an MPD for 2 years increased the airway passage because of an increase in the relative area of the pharynx by a mean of 9% in OSA patients and snorers. A mandibular posterior rotation and a proclination of the lower incisors were observed but considered modest.

Download full-text PDF

Source
http://dx.doi.org/10.1067/mod.2002.125993DOI Listing

Publication Analysis

Top Keywords

influence mandibular
8
mandibular protruding
8
protruding device
8
obstructive sleep
8
sleep apnea
8
2-year follow-up
8
linear distances
8
device airway
4
airway passages
4
passages dentofacial
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!