Purpose: To evaluate the accuracy of magnetic resonance (MR) imaging in the preoperative evaluation of potential living renal donors who are candidates for laparoscopic nephrectomy.

Materials And Methods: Twenty-eight donor candidates who underwent subsequent laparoscopic nephrectomy were examined by using a torso phased-array coil at 1.5 T. Gadolinium-enhanced MR angiograms, MR venograms, and MR urograms were obtained in all patients by using an interpolated three-dimensional T1-weighted spoiled gradient-echo sequence (3.4-6.8/1.2-2.3 [repetition time msec/echo time msec], 25 degrees -40 degrees flip angle). Interpretation of the MR images was used to assess the arterial, venous, and ureteral anatomy, as well as parenchymal masses and scarring, and findings were compared with the surgical findings in all patients. Statistical evaluation was performed, with the surgical findings as the reference standard.

Results: At MR imaging, 31 of 32 renal arteries and one of three early-branching arteries were identified correctly. The correct venous anatomy was identified in 23 of 28 patients, including a single left renal vein anterior to the aorta (n = 16), retroaortic left renal vein (n = 2), circumaortic left renal vein (n = 2), and single right renal vein (n = 3). A single collecting system in all harvested kidneys was identified correctly with MR urography. Overall, MR imaging correctly depicted vascular, ureteral, and parenchymal anatomy in 21 of 28 patients. Twenty-seven of 28 patients underwent successful laparoscopic donor nephrectomy on the basis of the MR findings. One procedure was converted to open nephrectomy on the basis of complex venous anatomy not prospectively identified on the MR images. The sensitivity and positive predictive value of MR imaging in correctly determining the combined vascular, ureteral, and parenchymal anatomy in the harvested kidney were 75% (21 of 28) and 95% (21 of 22), respectively.

Conclusion: Comprehensive gadolinium-enhanced MR imaging can depict the vascular anatomy, collecting system, and renal parenchyma preoperatively in patients who are candidates for laparoscopic living-donor nephrectomy.

Download full-text PDF

Source
http://dx.doi.org/10.1148/radiol.2252011671DOI Listing

Publication Analysis

Top Keywords

renal vein
16
candidates laparoscopic
12
left renal
12
imaging preoperative
8
preoperative evaluation
8
donor candidates
8
laparoscopic nephrectomy
8
surgical findings
8
identified correctly
8
venous anatomy
8

Similar Publications

Background: When inserting central venous catheters, inadvertent injury of major vessels is a rare yet critical complication. Direct surgery is sometimes overly invasive. This report describes a subclavian artery injury caused by inadvertent cannulation of a dialysis catheter, successfully treated with a covered stent.

View Article and Find Full Text PDF

Objectives: Vascular access thrombosis (VAT) is a common complication in patients with end-stage renal disease (ESRD), significantly impacting hemodialysis efficacy and patient survival. Currently, temporary dialysis access is typically established deep vein catheterization (VC), however, this method is highly invasive and associated with risks of infection and other complications. This study aims to explore the feasibility of using direct anastomosis indwelling needle puncture (DAINP) for temporary dialysis access.

View Article and Find Full Text PDF

Introduction: The length of the right renal vein is a crucial vascular factor in kidney transplantation. Its shorter length compared to the left renal vein complicates venous anastomosis. The aim of this article is to review the literature on this topic and provide data from our experience.

View Article and Find Full Text PDF

Objective: To assess tumour factors that reduce primary technical efficacy (PTE) from CT-guided renal cryoablation.

Methods: Patients were taken from the EuRECA registry between December 2014 and November 2020. To focus on tumour factors rather than individual technique, this study was limited to cases using CT and excluded procedures using cone beam, US, MRI, or laparoscopy.

View Article and Find Full Text PDF

Background: Understanding venous congestion is critical to the management of many illnesses, but assessing volume status can be challenging. The current gold standard for volume status assessment of right heart catheterization (RHC) is invasive, costly, and often unavailable. Venous Excess Ultrasound Score (VExUS) is a novel ultrasound protocol for to assessment of venous congestion using the inferior vena cava, hepatic, portal and renal veins.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!