Background: Different methods of replacing the aortic valve via a minimally invasive access have been reported in the recent literature. Although these strategies have clear advantages in terms of reduced surgical trauma, no further refinements in terms of cosmetic results have been made for women.
Methods: Aortic valve replacement was performed in 4 women via a right anterior submammary minithoracotomy without rib resection. The incision was made along the breast fold. The extracorporeal circulation was connected through the same access. Standard surgical technique and equipment were employed.
Results: No intraoperative complications or hospital deaths occurred. The 4 patients could be discharged home on the sixth postoperative day. The cosmetic result was excellent and the wound completely disappeared within the breast fold.
Conclusions: The advantages of the present method include the preservation of sternal integrity, early mobilization and rehabilitation and an excellent cosmetic result for women.
Download full-text PDF |
Source |
---|
Eur Heart J Cardiovasc Imaging
January 2025
Department of Cardiology, Istituto Auxologico Italiano, IRCCS, Milan, Italy.
Aims: This study evaluates whether multi-chamber myocardial deformation analysis using speckle tracking echocardiography (STE) can enhance validated current staging systems and improve risk stratification for patients with moderate-to-severe aortic stenosis (AS).
Methods And Results: We reanalyzed 2D, Doppler, and STE data obtained from two cohorts: derivation (654 patients, median age: 82 years; 51% men) and validation (237 patients, median age: 77 years; 55% men) with at least moderate AS (aortic valve area<1.5 cm2).
Eur J Cardiothorac Surg
January 2025
Department of Cardiac Surgery, University Hospital Quironsalud Madrid, Spain.
Objectives: The Ross procedure for aortic regurgitation (AR) and abnormal aortic valve morphologies is associated with an increased risk of autograft dilatation. Autograft support may ameliorate this problem. We analyzed the results for all haemodynamic lesions and the effect of autograft support.
View Article and Find Full Text PDFEur Heart J Case Rep
January 2025
The Second Department of Internal Medicine, University of Toyama, 2630 Sugitani, Toyama, Toyama 930-0194, Japan.
Background: Self-expanding valves used in transcatheter aortic valve implantation (TAVI) are designed to allow recapture and repositioning, facilitating optimal placement and mitigating conduction disturbances and paravalvular leakage. Here, we present a rare case in which the Navitor (Abbott Structural Heart, Santa Clara, CA, USA) could not be recaptured.
Case Summary: An 81-year-old Japanese woman with very severe aortic stenosis and a massively calcified nodule at the non-coronary cusp (NCC) underwent TAVI with a 25 mm Navitor valve.
Eur Heart J Case Rep
January 2025
Tehran Heart Center, Cardiovascular Diseases Research Institute, Tehran University of Medical Sciences, North Kargar Ave, Tehran 1411713138, Iran.
Background: Since the transcatheter valve-in-valve (ViV) procedure was introduced in 2007, a few cases of infective endocarditis (IE) following the ViV procedure have been reported, which can be predisposed by older age, pre-existing medical conditions, and procedural techniques. Paravalvular abscesses constitute a rare complication of IE, resulting from extending IE beyond the valve annulus, less commonly caused by species. This complication is more common in prosthetic valves, particularly bioprosthetic valves.