An investigation of air inlet velocity in simulating the dispersion of indoor contaminants via computational fluid dynamics.

Ann Occup Hyg

Department of Environmental Health Sciences, HESC, Room 311, Norman J Arnold School of Public Health, University of South Carolina, Columbia 29208, USA.

Published: November 2002

Computational fluid dynamics (CFD) is potentially a valuable tool for simulating the dispersion of air contaminants in workrooms. However, CFD-estimated airflow and contaminant concentration patterns have not always shown good agreement with experimental results. Thus, understanding the factors affecting the accuracy of such simulations is critical for their successful application in occupational hygiene. The purposes of this study were to validate CFD approaches for simulating the dispersion of gases and vapors in an enclosed space at two air flow rates and to demonstrate the impact of one important determinant of simulation accuracy. The concentration of a tracer gas, isobutylene, was measured at 117 points in a rectangular chamber [1 (L) x 0.3 (H) x 0.7 m (W)] using a photoionization analyzer. Chamber air flow rates were scaled using geometric and kinematic similarity criteria to represent a full-sized room at two Reynolds numbers (Re = 5 x 10(2) and 5 x 10(3)). Also, CFD simulations were conducted to estimate tracer gas concentrations throughout the chamber. The simulation results for two treatments of air inlet velocity (profiled inlet velocity measured in traverses across the air inlet and the assumption that air velocity is uniform across the inlet) were compared with experimental observations. The CFD-simulated 3-dimensional distribution of tracer gas concentration using the profiled inlet velocity showed better agreement qualitatively and quantitatively with measured chamber concentration, while the concentration estimated using the uniform inlet velocity showed poor agreement for both comparisons. For estimating room air contaminant concentrations when inlet velocities can be determined, this study suggests that using the inlet velocity distribution to define inlet boundary conditions for CFD simulations can provide more reliable estimates. When the inlet velocity distribution is not known, for instance for prospective design of dilution ventilation systems, the trials of several velocity profiles with different source, air inlet and air outlet locations may be useful for determining the most efficient workroom layout.

Download full-text PDF

Source
http://dx.doi.org/10.1093/annhyg/mef087DOI Listing

Publication Analysis

Top Keywords

inlet velocity
28
air inlet
16
inlet
12
simulating dispersion
12
tracer gas
12
velocity
9
air
9
computational fluid
8
fluid dynamics
8
air flow
8

Similar Publications

Sulfides as environmental stressors in Paracas Bay, Peru.

Mar Pollut Bull

January 2025

Facultad de Pesquería, Universidad Nacional Agraria La Molina, Av. La Molina S/N, La Molina, Lima 15024, Peru.

Paracas Bay, located in the Humboldt Current system, is a highly variable coastal environment where hypoxia (dissolved oxygen concentrations <2 mg L) has been reported as a persistent feature of bottom conditions. In addition to hypoxia, milky water events have been reported in the bay, most likely associated with the presence of sulfides (i.e.

View Article and Find Full Text PDF

Analyzing the uniformity of ammonia distribution at the inlet of selective catalytic reduction reactors is crucial for enhancing denitrification efficiency. To minimize ammonia slip while ensuring effective denitrification, this study examines ammonia flow characteristics in the SCR system under various zoning schemes. In scheme I, zones A1, A2, A3, and A4 predominantly influence the left, center, center-right, and far-right regions of the reactor inlet.

View Article and Find Full Text PDF

Stenosis causes the narrowing of arteries due to plaque buildup, which impedes blood flow and affects flow dynamics. This work numerically analyzes flow fluctuations in stenosed arteries under realistic physiological conditions (resting and exercise) and external body acceleration. The artery is inclined at angle , and blood rheology is modeled using a generalized power-law fluid.

View Article and Find Full Text PDF

The cavitation water jet cleaning and coating removal technique represents an innovative sustainable method for cleaning and removing coatings, with the nozzle serving as a crucial component of this technology. Developing an artificially submerged nozzle with a reliable structure and excellent cavitation performance is essential for enhancing cavitation water jets' cleaning and coating removal efficacy in an atmosphere environment (non-submerged state). This study is based on the shear flow cavitation mechanism of an angular nozzle, the resonance principle of an organ pipe, and the jet pump principle.

View Article and Find Full Text PDF

Coating Extrusion Characteristics of Thin-Walled Tubes for Catheters Using Thermoplastic Elastomer.

Polymers (Basel)

January 2025

Guangdong Engineering Technology Research Center of Small Household Appliances Innovation Design and Manufacturing, School of Mechanical Engineering, Guangdong Ocean University, Zhanjiang 524088, China.

During the production of medical thin-walled tubes, a thin coating layer is required. This requirement reduces the cross-sectional clearance area of the straight section flow channel formed by the mandrel and the die, leading to excessive pressure of the polymer melt at the shaping section, elevated die pressure, and backflow of the material melt, all of which directly impact the quality of the coating layer. To address these issues, this study conducted a non-isothermal numerical simulation of coating models both with and without a shaping section.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!