Because of the infrequent application of cardiac assist devices for postcardiotomy heart failure, most published reports include the results of learning curves from multiple surgeons. Between October 1986 and June 2001, a single surgeon used 35 Sarns Centrifugal Pumps as ventricular assist devices in 21 patients with severe hemodynamic compromise after open heart surgery (0.88% incidence). Patients' ages ranged from 39 to 77 (mean, 59.6 years). Three patients required right ventricular assist devices, 4 left ventricular assist devices, and 14 had biventricular assist devices. For all, the indication for application was inability to wean from cardiopulmonary bypass despite multiple inotropes and intraaortic balloon pumping. All were expected to be intraoperative deaths without further mechanical assistance. Patients were assisted from 2 to 434 h (median, 48 h). Fifteen patients (71.4%) were weaned from device(s), and 11 patients (52.4%) were hospital survivors. Actuarial survival in those dismissed from the hospital was 78% at 5 years and 39% at 10 years. Patients facing certain demise after cardiac surgery can be salvaged with temporary centrifugal mechanical assist. Results are competitive with that achieved with more sophisticated devices. Hospital survivors enjoy reasonable longevity.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1046/j.1525-1594.2002.07121.x | DOI Listing |
Objective: This study aims to evaluate the clinical efficacy of electro-pneumatic intracorporeal lithotripsy for the treatment of salivary gland stones.
Study Design: A prospective cohort study of patients diagnosed with obstructive salivary gland syndrome, where basket-assisted sialendoscopy alone failed to remove the calculi.
Setting: This study was conducted at the "Queen Maria" Military Hospital in Brașov, Romania, and a private practice, between February 2023 and May 2024.
Imaging Neurosci (Camb)
April 2024
Department of Electrical Engineering, Columbia University, New York, NY, United States.
Listeners with hearing loss have trouble following a conversation in multitalker environments. While modern hearing aids can generally amplify speech, these devices are unable to tune into a target speaker without first knowing to which speaker a user aims to attend. Brain-controlled hearing aids have been proposed using auditory attention decoding (AAD) methods, but current methods use the same model to compare the speech stimulus and neural response, regardless of the dynamic overlap between talkers which is known to influence neural encoding.
View Article and Find Full Text PDFMed Image Comput Comput Assist Interv
January 2025
Surgical & Interventional Engineering, King's College London, UK.
Embodied AI (E-AI) in the form of intelligent surgical robotics and other agents is calling for data platforms to facilitate its development and deployment. In this work, we present a cross-platform multimodal data recording and streaming software, MUTUAL, successfully deployed on two clinical studies, along with its ROS 2 distributed adaptation, MUTUAL-ROS 2. We describe and compare the two implementations of MUTUAL through their recording performance under different settings.
View Article and Find Full Text PDFClin Ophthalmol
January 2025
Department of Ophthalmology and Visual Sciences, W. K. Kellogg Eye Center, University of Michigan Medical School, Ann Arbor, MI, USA.
Purpose: To understand patient experiences using the iCare HOME tonometer through assessing ease of use, device usage patterns, proficiency, and patient comments.
Methods: We conducted a prospective survey-based cohort study of 19 patients (35 eyes) with glaucoma or glaucoma suspect diagnoses. Patients received training on home tonometer usage and were loaned the device for one week to measure intraocular pressure at home multiple times daily.
Rev Cardiovasc Med
January 2025
Cardiac Surgery, University of Cincinnati Medical Center, Cincinnati, OH 45202, USA.
Background: The fluorescent dye indocyanine green (ICG) has been used to identify anatomical structures intraoperatively in coronary artery bypass grafting (CABG). This study aimed to evaluate the feasibility of using ICG to assess graft patency and territorial distribution of myocardial reperfusion during CABG.
Methods: Porcine arrested hearts (n = 18) were used to evaluate territorial distribution of native coronary arteries and of a coronary bypass constructed with porcine saphenous vein graft (SVG) using ICG.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!