Background: During percutaneous cannulation, the diameter of the venous cannula is determined by the size of the access site. To limit this restriction, the Smart cannula (Cardiosmart Ltd., Fribourg, Switzerland) has been developed. Because its design allows self-expansion within the recipient vein, diameter restriction is limited to the access site.

Methods: In 6 calves (78 +/- 4.3 kg), the jugular vein and the carotid artery were cannulated through a cervicotomy. The Smart cannula was tested against three percutaneous cannulas with a diameter of 27, 25, and 21F, respectively. Stenotic percutaneous access to the vein was simulated by 1-cm wide tape encircling the vein that could be adjusted to a diameter of 27, 25, and 21F, respectively. The maximal flow rate, reached with stable reservoir level and a negative pressure of 44 mm Hg, was determined three times for each access size with the Smart cannula (one size fits all) and the corresponding percutaneous cannula successively.

Results: For an access size of 27F, the flow of the Smart cannula was 5.7 +/- 0.4 L/min and that of the percutaneous cannula was 4.3 +/- 0.2 L/min (p < 0.0001); for 25F, flow rates were 5.6 +/- 0.5 and 3.9 +/- 0.2 L/min, respectively (p < 0.0001); and for 21F, the flow rates were 4.3 +/- 0.4 and 2.7 +/- 0.3 L/min, respectively (p < 0.0001). The percentage increase of flow for the 27, 25, and 21F sizes were 34% +/- 9%, 42% +/- 16%, and 53% +/- 18%, respectively (one-way analysis of variance, p = 0.014).

Conclusions: For the present set-up, the Smart cannula outperforms commercially available percutaneous cannulas. The smaller the size of the insertion site, we observed a higher gain of flow with the Smart cannula.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0003-4975(02)03963-2DOI Listing

Publication Analysis

Top Keywords

smart cannula
24
+/- l/min
16
l/min 00001
12
cannula
10
+/-
10
venous cannula
8
percutaneous cannulas
8
diameter 21f
8
access size
8
percutaneous cannula
8

Similar Publications

Article Synopsis
  • The study investigates the effectiveness of Smart PDOs™ sutures for controlled silicon release and the Cartesian Technique™ for face lifting.
  • It involved both preclinical testing (using microscopy and spectroscopy) and clinical trials with 35 patients, focusing on improvements in skin turgidity and wrinkle reduction after treatment.
  • Results showed significant improvements in skin appearance and collagen quality, indicating that combining Smart PDOs™ with the Cartesian Technique™ is an effective method for enhancing skin rejuvenation.
View Article and Find Full Text PDF

A narrative review on the evolution and impact of smart cannulas in minimally invasive procedures.

Turk Gogus Kalp Damar Cerrahisi Derg

July 2024

Department of Cardiac Surgery, Anthea Hospital, GVM Care & Research, Bari, Italy.

Background: This study aimed to explore the evolution and impact of smart cannulas in enhancing outcomes and expanding the scope of minimally invasive cardiac surgery.

Methods: In this study, a comprehensive review of the relevant literature was conducted, focusing on articles detailing the development, implementation, and outcomes associated with smart cannulas in cardiac surgery. PubMed, MEDLINE, and Google Scholar databases were searched until January 2024 using specific search terms related to smart cannulas and cardiac surgery.

View Article and Find Full Text PDF

The effect of mechanical ventilation compared to high-flow nasal cannula on gastric residual volume and reflux events using novel automated technology.

Clin Nutr ESPEN

October 2024

Department of General Intensive Care and Institute for Nutrition Research, Rabin Medical Center, Israel; Sackler Medical School, Tel Aviv University, Israel.

Article Synopsis
  • This study investigates how high flow nasal cannula (HFNC) oxygen therapy affects gastric reflux events and gastric residual volumes (GRV) in patients who were mechanically ventilated and then extubated.
  • Using the smART+ Platform, researchers compared reflux events and GRV before and after patients switched to HFNC therapy.
  • The results indicated that while GRV increased significantly on HFNC, the frequency of major reflux events showed no significant change between the two patient states.
View Article and Find Full Text PDF

Background: Over recent years, technological advances in wearables have allowed for continuous home monitoring of heart rate and oxygen saturation. These devices have primarily been used for sports and general wellness and may not be suitable for medical decision-making, especially in saturations below 90% and in patients with dark skin color. Wearable clinical-grade saturation of peripheral oxygen (SpO) monitoring can be of great value to patients with chronic diseases, enabling them and their clinicians to better manage their condition with reliable real-time and trend data.

View Article and Find Full Text PDF

Background: Failure to reach full oral feeding remains a significant barrier for premature infants to discharge home. Postmenstrual age (PMA) at first oral feeding is significantly associated with the length of hospital stay (LOS).

Methods: Single-center QI to introduce oral feeding to infants on high-flow nasal cannula (HFNC) by reducing the flow to 2 L during feeds.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!