A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Measurement of coronary flow reserve in the anterior and posterior descending coronary arteries by transthoracic Doppler ultrasound. | LitMetric

We describe for the first time transthoracic Doppler ultrasound assessment of coronary flow reserve (CFR) in both the posterior descending (PDA) and left anterior descending (LAD) coronary arteries. CFR (hyperemic/resting diastolic flow velocity ratio) was measured by 90-second intravenous adenosine infusion (140 microg/kg/min). Baseline PDA flow was detected in 62 of 81 subjects (76%), and the CFR was measurable in 44 of them (54%) because of adenosine-induced hyperventilation. According to angiography, these 44 subjects were divided into 3 groups: group 1 (0% to 29% stenosis), group 2 (30% to 69% stenosis), and group 3 (> or =70% stenosis). PDA CFR was 2.62 +/- 0.25 in 17 patients in group 1, 2.33 +/- 0.32 in 9 patients in group 2, and 1.40 +/- 0.54 in 18 patients in group 3 (F = 41.83, p <0.0001). LAD CFR was 3.31 +/- 0.54 in 15 patients in group 1, 2.49 +/- 0.71 in 10 patients in group 2, and 1.12 +/- 0.49 in 19 patients in group 3 (F = 65.68, p <0.0001). A cut-off of <2 identified > or =70% stenosis in both of the arteries supplying the PDA and in the LAD. Noninvasive measurement of PDA CFR is feasible and may improve with technologic advancement and the use of selective adenosine receptor agonists, thus preventing hyperventilation.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0002-9149(02)02666-8DOI Listing

Publication Analysis

Top Keywords

patients group
12
coronary flow
8
flow reserve
8
posterior descending
8
coronary arteries
8
transthoracic doppler
8
doppler ultrasound
8
stenosis group
8
group
6
measurement coronary
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!