AI Article Synopsis

Article Abstract

Background: We evaluated the usefulness of intravascular ultrasound (IVUS) in the non-uniform distribution of in-stent neointimal hyperplasia, comparing macroscopic measurements with IVUS-guided histomorphometry.

Methods: Coronary stenting was performed in 45 left coronaries of 39 pigs, using 18 Tenax (Biotronik Gmbh and Co., Berlin, Germany), 11 bare Genius (Eurocor, Bonn, Germany), 10 polymer-coated Genius (Eurocor) and six Biodivysio Matrix LO (Biodivysio Ltd, Farnham, Surrey, UK) stents. After 4 weeks, coronary angiography and IVUS with automatic pullback were performed. IVUS images were analysed using three-dimensional analysis (EchoPlaque 2; INDEC Systems Inc., Mountain View, California, USA). The stented segments were formalin fixed, embedded in Technovit 9100 and cut to 4-8 microm thick slides. The most diseased in-stent segment was 4.49 +/- 4.54 mm away from the distal stent edge assessed by IVUS. Sections of these segments were stained for histomorphometry.

Results: A significant correlation was found between IVUS-guided histomorphometry and three-dimensional IVUS measurements of maximal intimal thickness (r = 0.6985, P < 0.005) and area (r = 0.7736, P < 0.001). Macroscopic measurements resulted in comparable maximal intimal thickness (0.83 +/- 0.43 mm compared with 0.81 +/- 0.46 mm) and area (4.44 +/- 1.73 mm2 compared with 3.45 +/- 1.55 mm2) by IVUS and histomorphometry, respectively. Although stent length, diameter, nominal inflation pressure and time and injury score did not differ between the stents, bare Genius stents resulted in significant smaller neointimal volume compared to Tenax, polymer-coated Genius and Biodivysio stents: 24.46 +/- 4.98 mm3 compared with 59.18 +/- 26.41, 60.46 +/- 10.03 and 61.41 +/- 16.27 mm3, respectively (P < 0.05).

Conclusion: The significant correlation between IVUS-guided histomorphometry and IVUS measurements confirms the usefulness of IVUS in evaluation of experimental in-stent restenosis. Implantation of bare Genius stents resulted in significant lower neointimal hyperplasia compared to Tenax, polymer-coated Genius or phosphorylcholine-coated Biodivysio stents.

Download full-text PDF

Source
http://dx.doi.org/10.1097/00019501-200208000-00007DOI Listing

Publication Analysis

Top Keywords

bare genius
12
polymer-coated genius
12
+/-
9
ivus
8
neointimal hyperplasia
8
macroscopic measurements
8
genius eurocor
8
correlation ivus-guided
8
ivus-guided histomorphometry
8
ivus measurements
8

Similar Publications

Background: The coronary artery with an interarterial course CAIAC is the most threatening coronary anomaly, especially if it concerns the left coronary. Percutaneous coronary intervention PCI is scarcely described given its low prevalence and lack of long-term outcome data. Therefore, we assessed through this case series the feasibility and safety of PCI in this population.

View Article and Find Full Text PDF

Technical overview on the MiStent coronary stent.

Minerva Cardioangiol

October 2016

MiCell Technologies, Durham, NC, USA -

Drug-eluting stents (DES) have dramatically improved the long-term efficacy of percutaneous coronary intervention (PCI). Over the last decade there have been numerous advances in DES platforms, however, all but one currently approved DES in the United States and many of the approved DES worldwide still have 3 common features: a metal stent platform, an anti-proliferative drug, and a permanent polymer. In this context, the polymer is critical to control drug release, but the polymer serves no purpose after the drug is eluted.

View Article and Find Full Text PDF

Background: We evaluated the usefulness of intravascular ultrasound (IVUS) in the non-uniform distribution of in-stent neointimal hyperplasia, comparing macroscopic measurements with IVUS-guided histomorphometry.

Methods: Coronary stenting was performed in 45 left coronaries of 39 pigs, using 18 Tenax (Biotronik Gmbh and Co., Berlin, Germany), 11 bare Genius (Eurocor, Bonn, Germany), 10 polymer-coated Genius (Eurocor) and six Biodivysio Matrix LO (Biodivysio Ltd, Farnham, Surrey, UK) stents.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!