Objectives: We sought to evaluate the long-term effects of alternative right ventricular pacing sites on myocardial function and perfusion.
Background: Previous studies have demonstrated that asynchronous ventricular activation due to right ventricular apical (RVA) pacing alters regional myocardial perfusion and functions.
Methods: We randomized 24 patients with complete atrioventricular block to undergo permanent ventricular stimulation either at the RVA (n = 12) or right ventricular outflow (RVOT) (n = 12). All patients underwent dipyridamole thallium myocardial scintigraphy and radionuclide ventriculography at 6 and 18 months after pacemaker implantation.
Results: After pacing, the mean QRS duration was significantly longer during RVA pacing than during RVOT pacing (151 +/- 6 vs. 134 +/- 4 ms, p = 0.03). At six months, the incidence of myocardial perfusion defects (50% vs. 25%) and regional wall motion abnormalities (42% vs. 25%) and the left ventricular ejection fraction (LVEF) (55 +/- 3% vs. 55 +/- 1%) were similar during RVA pacing and RVOT pacing (p > 0.05). However, at 18 months, the incidence of myocardial perfusion defects (83% vs. 33%) and regional wall motion abnormalities (75% vs. 33%) were higher and LVEF (47 +/- 3 vs. 56 +/- 1%) was lower during RVA pacing than during RVOT pacing (all p < 0.05). Patients with RVA pacing had a significant increase in the incidence of myocardial perfusion defects (p < 0.05) and a decrease in LVEF (p < 0.01) between 6 and 18 months, but patients with RVOT pacing did not (p > 0.05).
Conclusions: This study demonstrates that preserved synchronous ventricular activation with RVOT pacing prevents the long-term deleterious effects of RVA pacing on myocardial perfusion and function in patients implanted with a permanent pacemaker.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/s0735-1097(02)02169-1 | DOI Listing |
J Cardiovasc Electrophysiol
October 2024
Division of Electrophysiology, Texas Health Heart and Vascular Specialists, Fort Worth, Texas, USA.
Introduction: It remains unclear if pacing induced cardiomyopathy (PICM) may be minimized by standard pacing of the right ventricle (RV) at sites other than the RV apex. The purpose of this study is to compare the relative frequency of PICM in a population of patients paced at either the superficial RV mid septum (RVMS) or RV apex (RVA), and other outcomes that may differ between these sites.
Methods And Results: A retrospective evaluation was performed on all patients undergoing pacemaker implantation between 2011 and 2022.
Front Cardiovasc Med
April 2024
Department of Cardiology, Cardiovascular Center, Beijing Friendship Hospital, Capital Medical University, Beijing, China.
J Biomed Sci
April 2024
Graduate Institute of Clinical Medicine, College of Medicine, Taipei Medical University, 250 Wu-Hsing Street, Taipei, 11031, Taiwan.
Background: Myocarditis substantially increases the risk of ventricular arrhythmia. Approximately 30% of all ventricular arrhythmia cases in patients with myocarditis originate from the right ventricular outflow tract (RVOT). However, the role of NLRP3 signaling in RVOT arrhythmogenesis remains unclear.
View Article and Find Full Text PDFFront Physiol
December 2023
Department of Medical Physiology, University Medical Center Utrecht, Utrecht, Netherlands.
An electrical storm of Torsade de Pointes arrhythmias (TdP) can be reproducibly induced in the anesthetized chronic AV-block (CAVB) dog by infusion of the I-blocker dofetilide. Earlier studies showed that these arrhythmias 1) arise from locations with high spatial dispersion in repolarization (SDR) and 2) can be suppressed by high-rate pacing. We examined whether suppression of TdP by high-rate pacing is established through a decrease in SDR in the CAVB dog.
View Article and Find Full Text PDFEuropace
December 2023
Arrhythmia Unit, Hospital Universitario Virgen de las Nieves, Avenida de las Fuerzas Armadas, 18014 Granada, Spain.
Aims: The compatibility of cardiac pacing with the presence of a subcutaneous implantable cardioverter-defibrillator (S-ICD) has been investigated, but S-ICD screening test results have not been compared among different pacing sites. The objective was to compare S-ICD screening results among different cardiac pacing sites and to assess the electrocardiographic predictors of success.
Methods And Results: This prospective single-centre study conducted automated S-ICD screening in 102 carriers of cardiac pacing devices in conduction system (CSP), biventricular (BVP), right ventricular outflow tract (RVOT), or right ventricular apex (RVA) pacing sites.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!