A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Carotid artery auscultation--anachronism or useful screening procedure? | LitMetric

Carotid bruits are supposed to indicate the presence of high-grade common carotid or extracranial internal carotid artery stenosis in a large proportion of patients. Using a stethoscope, we prospectively auscultated 273 carotid arteries of 145 patients blinded to the results of a complete extracranial and intracranial Doppler investigation including extracranial color-coded duplex ultrasound. Fifty-four arteries showed stenosis of > or = 50%-99%, or occlusion of the extracranial internal or the common carotid artery. In 25 of these arteries, a bruit was present. In 9 out of 16 patients with extracranial stenosis from 70%-99%, a bruit was detected. In one additional patient with a middle-grade external carotid artery stenosis, a bruit was also present. In seven additional patients, a bruit was present in the absence of any carotid artery stenosis, cardiac vitium or goiter. The sensitivity of carotid auscultation for the detection of a 70%-99% stenosis of the common or extracranial internal carotid artery was 56% and specificity was 91%. The positive predictive value of a bruit found during carotid auscultation was 27%, and the negative predictive value of a normal auscultation was 97%. Carotid auscultation is a useful screening procedure in the detection of carotid stenosis or occlusion, but requires confirmation by carotid ultrasound.

Download full-text PDF

Source
http://dx.doi.org/10.1179/016164102101200618DOI Listing

Publication Analysis

Top Keywords

carotid artery
24
carotid
14
extracranial internal
12
artery stenosis
12
carotid auscultation
12
common carotid
8
internal carotid
8
stenosis
7
extracranial
6
artery
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!