LiF:Mg,Cu,P 'pin worms': miniature detectors for brachytherapy dosimetry.

Radiat Prot Dosimetry

Department of Radiation Oncology, Newcastle Mater Misericordiae Hospital, Waratah, NSW, Australia.

Published: April 2003

Dose measurements in brachytherapy 192Ir implants are often difficult due to large dose gradients and complex photon spectra. Therefore, tissue-equivalent detectors with a high spatial resolution, such as the highly promising LiF:Mg,Cu,P thermoluminescent detectors (TLDs) are required. It was the aim of the present work to ascertain if miniature LiF:Mg,Cu,P TLDs can effectively measure the dose distribution around 192Ir implants. 'Pin worm' TLDs (type MCP, diameter 0.6 mm, length 2 mm) were compared with GR-200R (SSDL, Beijing) rods cut in half. The TLDs were tested for reproducibility and energy dependence using high dose rate (HDR) and low dose rate (LDR) brachytherapy units. 192Ir measurements were performed in a tissue equivalent phantom accommodating hollow needles and catheters routinely used in brachytherapy. Pin worms had an average reproducibility of less than +/-2% (1 SD) and a detection limit of less than 10 microGy. The small dimensions of the pin worms allowed their placement within brachytherapy needles and catheters. The measured relative dose distribution was in good agreement with the predictions of a computerised treatment planning system (ADAC Pinnacle); however, limitations in the TLD energy correction did not allow for absolute dose comparison.

Download full-text PDF

Source
http://dx.doi.org/10.1093/oxfordjournals.rpd.a006012DOI Listing

Publication Analysis

Top Keywords

192ir implants
8
dose distribution
8
dose rate
8
needles catheters
8
pin worms
8
dose
7
brachytherapy
5
lifmgcup 'pin
4
'pin worms'
4
worms' miniature
4

Similar Publications

On the impact of improved dose calculation accuracy in clinical treatment planning for superficial high-dose-rate brachytherapy of extensive scalp lesions.

Phys Imaging Radiat Oncol

October 2024

Division of Medical Physics, Department of Radiation Oncology, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, German Cancer Consortium (DKTK), Partner Site DKTK, Freiburg, Germany.

Article Synopsis
  • TG-43 dose calculations in HDR brachytherapy often overlook variations in tissue density and scattering effects, leading to inaccuracies.
  • Model-based dose calculation algorithms (MBDCAs) were introduced to enhance precision in high-dose-rate (HDR) treatments, especially for extended scalp lesions.
  • This study found that MBDCAs provided more accurate dose estimations compared to TG-43, with discrepancies reduced to 2%-6% versus the 10%-23% overestimations seen with TG-43 at greater distances from the implant.
View Article and Find Full Text PDF

Purpose: The aim of this study was a retrospective dosimetric comparison of iridium-192 (Ir) high-dose-rate (HDR) interstitial brachytherapy plans using model-based dose calculation algorithm (MBDCA) following TG-186 recommendations and TG-43 dosimetry protocol for breast, head-and-neck, and lung patient cohorts, with various treatment concepts and prescriptions.

Material And Methods: In this study, 59 interstitial Ir HDR brachytherapy cases treated in our center (22 breast, 22 head and neck, and 15 lung) were retrospectively selected and re-calculated with TG-43 dosimetry protocol as well as with Acuros BV dose calculation algorithm, with dose to medium option based on computed tomography images. Treatment planning dose volume parameter differences were determined and their significance was assessed.

View Article and Find Full Text PDF

Objectives: Low-dose-rate brachytherapy (LDR-BT) with Au grains and Ir pins is an essential treatment option for oral cancer due to its high rate of local control and low invasiveness. However, the radiation exposure of medical radiation workers is concerning. Thus, we aimed to determine the radiation dose delivered to medical radiation workers during LDR-BT using Au grains and Ir pins for oral cancer.

View Article and Find Full Text PDF

Purpose: The current protocol for use of the image-guided adaptive brachytherapy (IGABT) procedure entails transport of a patient between the treatment room and the 3-D tomographic imaging room after implantation of the applicators in the body, which movement can cause position displacement of the applicator. Moreover, it is not possible to track 3-D radioactive source movement inside the body, even though there can be significant inter- and intra-fractional patient-setup changes. In this paper, therefore, we propose an online single-photon emission computed tomography (SPECT) imaging technique with a combined C-arm fluoroscopy X-ray system and attachable parallel-hole collimator for internal radioactive source tracking of every source position in the applicator.

View Article and Find Full Text PDF

Purpose: Manufacturing of miniaturized high activity iridium-192 (Ir) sources have been made a market preference in modern brachytherapy. Smaller dimensions of the sources are flexible for smaller diameter of the applicators, and it is also suitable for interstitial implants. Presently, cobalt-60 (Co) sources have been commercialized as an alternative to Ir sources for high-dose-rate (HDR) brachytherapy, since Co source have an advantage of longer half-life comparing with Ir source.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!