A method for the detection and screening of catalytic anti-DNA antibodies.

J Immunol Methods

Laboratoire d'Ingénierie des Anticorps, Institut Pasteur, 25 rue du Dr. Roux, 75724 Paris Cedex 15, France.

Published: November 2002

We have developed a microtiter plate assay for the detection and screening of anti-DNA hydrolytic antibodies. The affinity-linked oligonucleotide nuclease assay (ALONA) makes use of substrates with a digoxigenin on the 5'-end of the 3'-biotinylated DNA strands. The substrate binds specifically to the wells of streptavidin-coated microtiter plates where the reaction takes place. Uncleaved substrate retains the digoxigenin label, which is then detected with an enzyme-labeled anti-digoxigenin antibody. We first assessed the efficiency of this assay by measuring S1 nuclease and DNase I activities and the inhibitory effect of EDTA on the reaction. The ALONA procedure was then successfully applied to the screening of a high number of hybridoma clones derived from nonimmunized (NZB x NZW)F1 mice with spontaneous lupus erythematosus. We detected three potential catalytic antibodies and investigated their substrate specificity. Overall, our findings demonstrate the value of the ALONA method for high throughput screening of potential nucleases and catalytic antibodies. Although this assay was designed for the selection of catalysts active in DNA hydrolysis, it can be adapted to detect most types of substrate cleavage reaction.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0022-1759(02)00231-4DOI Listing

Publication Analysis

Top Keywords

detection screening
8
catalytic antibodies
8
method detection
4
screening
4
screening catalytic
4
catalytic anti-dna
4
antibodies
4
anti-dna antibodies
4
antibodies developed
4
developed microtiter
4

Similar Publications

The intelligent identification of wear particles in ferrography is a critical bottleneck that hampers the development and widespread adoption of ferrography technology. To address challenges such as false detection, missed detection of small wear particles, difficulty in distinguishing overlapping and similar abrasions, and handling complex image backgrounds, this paper proposes an algorithm called TCBGY-Net for detecting wear particles in ferrography images. The proposed TCBGY-Net uses YOLOv5s as the backbone network, which is enhanced with several advanced modules to improve detection performance.

View Article and Find Full Text PDF

The relationship between serum vitamin C levels and high-sensitivity C-reactive protein in children.

Sci Rep

December 2024

Department of Clinical Laboratory, Children's Hospital Affiliated to Zhengzhou University, Zhengzhou Key Laboratory of Children's Infection and Immunity, Zhengzhou, 450000, P. R. China.

The relationship between vitamin C nutritional status and inflammation has garnered increasing attention, but studies in younger populations are limited. This study aimed to investigate the association between serum vitamin C and high-sensitivity C-reactive protein (hs-CRP) levels in children and adolescents. A cross-sectional analysis was conducted using data from the National Health and Nutrition Examination Survey (NHANES).

View Article and Find Full Text PDF

Manual segmentation of lesions, required for radiotherapy planning and follow-up, is time-consuming and error-prone. Automatic detection and segmentation can assist radiologists in these tasks. This work explores the automated detection and segmentation of brain metastases (BMs) in longitudinal MRIs.

View Article and Find Full Text PDF

Pathogenic activating mutations in the fibroblast growth factor receptor 3 (FGFR3) drive disease maintenance and progression in urothelial cancer. 10-15% of muscle-invasive and metastatic urothelial cancer (MIBC/mUC) are FGFR3-mutant. Selective targeting of FGFR3 hotspot mutations with tyrosine kinase inhibitors (e.

View Article and Find Full Text PDF

In optical imaging of solid tumors, signal contrasts derived from inherent tissue temperature differences have been employed to distinguish tumor masses from surrounding tissue. Moreover, with the advancement of active infrared imaging, dynamic thermal characteristics in response to exogenous thermal modulation (heating and cooling) have been proposed as novel measures of tumor assessment. Contrast factors such as the average rate of temperature changes and thermal recovery time constants have been investigated through an active thermal modulation imaging approach, yielding promising tumor characterization results in a xenograft mouse model.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!