Hemiarthroplasty can be an effective treatment for 4-part fractures of the proximal humerus; however, results are often unpredictable. Proper surgical technique is critical for success. Reconstruction of the displaced tuberosities should attempt to impart maximal interfragmentary stability. To our knowledge, a comparison of different tuberosity reconstruction methods has not been reported. We evaluated 5 techniques of tuberosity reattachment on 8 humeri. Four-part fractures were simulated by an oscillating saw in fresh-frozen cadaveric shoulders. In the control construct, the greater and lesser tuberosities were attached to the humeral shaft with nylon strap ties (2.4 x l mm) applied at 9.1 N with closure of the rotator interval. Five anatomic reconstructions were then performed:(1) the control tuberosities were attached to each other with strap ties, and (2) the control tuberosities were attached to each other with strap ties, incorporating the anterior fin of the prosthesis. To each of these 3 constructs, a circumferential cerclage (4.8 x 1.25-mm strap tie) applied at 39.2 N was placed around the tuberosities and incorporated into the medial hole of the prosthesis (techniques 3, 4, and 5). Through use of a robot articulator at a rate of 10 degrees /s, passive external rotation from 0 degrees to 60 degrees was performed on the control and the 5 test constructs of each specimen. Interfragmentary displacement of the bony fragments was measured with mercury strain gauges and strain calculated. This strain was minimal and statistically less (P <.05) in those constructs in which a cerclage was used. Incorporation of the nylon strap into the fin of the prosthesis did not enhance stability. In those constructs in which a cerclage was used, maximal displacement was 0.14 +/- 0.7 mm (38% +/- 19% strain), as compared with 0.72 +/- 0.5 mm (204% +/- 133% strain) without it. Reconstruction of 4-part proximal humerus fractures with hemiarthroplasty should incorporate a circumferential medial cerclage. This will decrease interfragmentary motion and strain, maximize fracture stability, and facilitate postoperative rehabilitation.

Download full-text PDF

Source
http://dx.doi.org/10.1067/mse.2002.126098DOI Listing

Publication Analysis

Top Keywords

tuberosities attached
12
strap ties
12
tuberosity reattachment
8
control tuberosities
8
attached strap
8
tuberosities
5
stability tuberosity
4
reattachment proximal
4
proximal humeral
4
humeral hemiarthroplasty
4

Similar Publications

Background: Patients undergoing reverse shoulder arthroplasty (RSA) for rotator cuff arthropathy may present with an external rotation (ER) lag due to posterior rotator cuff insufficiency. As a result, the addition of a latissimus dorsi (LD) tendon transfer in combination with RSA has become increasingly utilized. Initial descriptions of LD tendon transfer involved rerouting of the LD tendon posterior to the long head of the triceps tendon.

View Article and Find Full Text PDF

Purpose: It is not known where the anatomical axis of rotation on the tibial side will be in kinematic alignment (KA), a rapidly expanding area of total knee arthroplasty (TKA) alignment technique today. The purpose of this study was to define the tibial axis for KA-TKA.

Methods: Fifty patients who underwent computed tomography (CT) examination of the lower extremities at a single institution were included.

View Article and Find Full Text PDF

Tissue Oxygenation in Individuals with Spinal Cord Injury: A Pilot Study.

Adv Exp Med Biol

October 2024

Institute of Complementary and Integrative Medicine, University of Bern, Bern, Switzerland.

Article Synopsis
  • Pressure injuries (PI) are serious tissue lesions that heal slowly and can lead to infections, primarily affecting individuals with spinal cord injuries (SCI) due to their reduced mobility and sensation.
  • A new alert system utilizing a textile-based near-infrared spectroscopy (NIRS) sensor was developed to monitor tissue oxygen levels (StO) in high-risk areas, such as the buttocks, to prevent PIs.
  • Initial tests demonstrated that ST decreased during prolonged sitting, with SCI subjects experiencing a sharper decline, but recovery was observed, showing the sensor's effectiveness without causing skin irritation.
View Article and Find Full Text PDF
Article Synopsis
  • Spondyloarthritis is an inflammatory condition that can cause tendon adhesions and sacroiliitis, and this case focuses on reactive arthritis (ReA) triggered by a Chlamydia infection.
  • The patient experienced pain in the hip, lower back, and right shoulder, with MRI results showing inflammation at various tendon sites, but without sacroiliitis.
  • Notably, this case is the first to report shoulder lesions in ReA linked to infection and highlights that these lesions can show both adhesive inflammation and bone marrow edema along with rotator cuff issues.
View Article and Find Full Text PDF
Article Synopsis
  • Displaced avulsion fractures of the calcaneal tuberosity often result from osteoporosis or severe injuries, posing risks like wound breakdown and hardware failure, especially in older patients with health issues.
  • The authors introduce a new technique using the TightRope Attachable Button System (ABS) for treating complex Beavis type II 'beak' calcaneal fractures, adapting methods from ACL surgeries.
  • A successful case is presented involving a 67-year-old woman with multiple health conditions who underwent this innovative procedure, demonstrating no complications after four years.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!