The uncemented Bi-Contact total hip arthroplasty.

J Arthroplasty

Derbyshire Royal Infirmary, Derby, United Kingdom.

Published: October 2002

We reviewed a consecutive series of 153 uncemented Bi-Contact (Aesculap, Tuttlingen, Germany) total hip arthroplasties (THAs) in 138 patients who had been followed for at least 5 years (mean, 6.8 years; range, 5-9 years). The Bi-Contact uncemented THA consists of a straight femoral stem made of titanium alloy. The proximal portion of the stem is titanium plasma-sprayed. The cup is press-fit with or without hydroxyapatite coating with a facility for anchoring screws with a snap-fit polyethylene liner. The mean age of the patients was 70.8 years (range, 41-94 years). The mean preoperative Harris hip score of 41 (range, 20-80) improved postoperatively to a mean of 92 (range, 56-96). Three acetabular cups were revised for aseptic loosening, and 1 cup was revised for recurrent dislocation. To date, none of the stems have been revised for aseptic loosening. Radiographic evaluation of the remaining 149 hips revealed that the acetabular cup was stable in 146 hips and possibly unstable in the remaining 3 cases with nonprogressive osteolysis behind the cup. None of the stems showed any evidence of instability. Using the recommendation of revision as the endpoint, the cumulative survival for the prosthesis was 97.3% at a mean follow-up of 6.8 years (95% confidence interval, 95.9-99.4), with stem survival of 100%. In the medium-term, these results are comparable to cemented primary THA and justify the continued use of this prosthesis.

Download full-text PDF

Source
http://dx.doi.org/10.1054/arth.2002.34523DOI Listing

Publication Analysis

Top Keywords

uncemented bi-contact
8
total hip
8
years range
8
stem titanium
8
revised aseptic
8
aseptic loosening
8
years
6
bi-contact total
4
hip arthroplasty
4
arthroplasty reviewed
4

Similar Publications

Current practice in primary total hip replacement was investigated by postal survey in 125 university hospitals of the European Union (EU). Most hospitals (78.4%) use a hip register and implant cemented as well as uncemented stems (72.

View Article and Find Full Text PDF

The uncemented Bi-Contact total hip arthroplasty.

J Arthroplasty

October 2002

Derbyshire Royal Infirmary, Derby, United Kingdom.

We reviewed a consecutive series of 153 uncemented Bi-Contact (Aesculap, Tuttlingen, Germany) total hip arthroplasties (THAs) in 138 patients who had been followed for at least 5 years (mean, 6.8 years; range, 5-9 years). The Bi-Contact uncemented THA consists of a straight femoral stem made of titanium alloy.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!