Objective: To compare the diagnostic accuracy of gray scale sonography and color Doppler imaging in the differential diagnosis of adnexal malignancies from benign complex pelvic masses in a multicenter prospective study.

Methods: The study was performed as a collaborative work at 3 European university departments of obstetrics and gynecology. A total of 826 complex pelvic masses on which transvaginal sonography and evaluation of cancer antigen 125 plasma concentrations were performed before surgical exploration were included in the study. The scanning procedure was the same in the 3 institutions. An adnexal mass was first studied in gray scale sonography, and a probable histologic type was predicted. Second, solid excrescences or solid portions of the tumor were evaluated for vascular flow with color Doppler sonography (conventional or power). A mass was graded malignant if flow was shown within the excrescences or solid areas and benign if there was no flow. The overall agreement between the test result and the actual outcome was calculated by kappa statistics.

Results: Color Doppler evaluation was more accurate in the diagnosis of adnexal malignancies in comparison with gray scale sonography (kappa = 0.82 and 0.65, respectively) because of significantly higher specificity (0.94 versus 0.84; P < .001). The evaluation of the cancer antigen 125 plasma concentration did not seem to increase the accuracy of either method.

Conclusions: The evaluation of vessel distribution by color Doppler sonography in complex adnexal cysts seems to increase the diagnostic accuracy of gray scale sonography in the detection of adnexal malignancies in a large study population.

Download full-text PDF

Source
http://dx.doi.org/10.7863/jum.2002.21.10.1105DOI Listing

Publication Analysis

Top Keywords

color doppler
20
adnexal malignancies
16
gray scale
16
scale sonography
16
complex pelvic
12
doppler sonography
12
diagnosis adnexal
12
evaluation vessel
8
vessel distribution
8
distribution color
8

Similar Publications

Objective: Elevated intracranial pressure (ICP), a common complication in traumatic brain injuries (TBI), can lead to optic nerve sheath diameter (ONSD) enlargement and flow spectrum changes from the internal carotid artery (ICA) to middle cerebral artery (MCA). This study will investigate the use of Cervical-Cerebral Arterial Ultrasound (CCAU) for non-invasive ICP assessment and evaluating the related indices' clinical utility in TBI patients with decompressive craniotomy (DC).

Methods: ONSD and flow spectrum changes were measured within 24 h after DC in 106 patients via ultrasonic ONSD measurement and CCAU, simultaneously.

View Article and Find Full Text PDF

Color doppler blood flow analysis in circumscribed choroidal hemangioma.

Arq Bras Oftalmol

January 2025

Department of Ophthalmology & Visual Sciences, Escola Paulista de Medicina, Universidade Federal de São Paulo, São Paulo, SP, Brazil.

Purpose: To evaluate if color Doppler can detect internal blood flow in circumscribed choroidal hemangioma.

Methods: This cross-sectional study examined seven eyes of seven participants with circumscribed choroidal hemangiomas, with or without prior treatment. B-scan ultrasound and color Doppler were used to assess the dimensions, topographical distribution, and internal blood flow of the affected eyes.

View Article and Find Full Text PDF

Optimizing the life of vascular access during follow-up.

J Cardiovasc Surg (Torino)

February 2025

Department of Vascular Surgery, ASST Settelaghi Universitary Teaching Hospital, University of Insubria, Varese, Italy.

Optimizing the longevity of vascular access in hemodialysis patients remains a critical aspect of patient care, given the significant role of arteriovenous fistulas (AVFs) and arteriovenous grafts (AVGs) in enabling effective dialysis. Vascular access complications, such as stenosis, thrombosis, and cannulation-related damage, continue to challenge both the functionality and the sustainability of these access points. Recent advancements underscore the importance of a robust follow-up strategy, integrating clinical evaluations with diagnostic tools like color Doppler ultrasound (CDU) and emerging interventional approaches such as drug-coated balloon (DCB) angioplasty.

View Article and Find Full Text PDF

Aim: The current investigation aimed to evaluate the accuracy of ultrasonography and color Doppler performed in the diagnosis of intraosseous jaw lesions.

Materials And Methods: A total of 30 patients with intraosseous jaw lesions between the ages of 12 and 60 were selected for the present study. For every jaw lesion, a preliminary diagnosis was done using preoperative conventional radiographs.

View Article and Find Full Text PDF

Background: Superior caval vein obstruction is a rare complication of endocardial pacing lead implantation that can result in a right to left shunt.

Case Summary: A 3-year-old child with type 2 Brugada syndrome presented with mild cyanosis post-endocardial pacing implantation due to evolutionary right superior caval vein obstruction. This obstruction resulted in a right to left shunt across a previously unrecognized patent levo-atrial cardinal vein associated with partial anomalous pulmonary venous drainage.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!