Background: To evaluate the efficacy of a modification of the composite sequential femorocrural bypass graft that we adopted in 1985, a retrospective case-note study was undertaken. The grafts combined a prosthetic femoropopliteal section with a popliteal to crural section with autologous vein, linked via a common intermediate anastomosis sited on the above-knee popliteal artery.

Patients And Methods: Between 1985 and 2000, 68 grafts of this type were constructed in 65 patients with critical ischemia of the lower limb and insufficient autologous vein for construction of an all venous bypass. Reasons for insufficient long saphenous vein included previous lower limb bypass in 33 cases, phlebitis in 16 cases, venous hypoplasia in eight cases, and previous varicose vein surgery in seven cases. Distal anastomoses were carried out to the peroneal artery in 26 cases, the anterior tibial artery in 17 cases, the posterior tibial artery in 17 cases, and the pedal arteries in eight cases. Sources of vein included the long saphenous vein in 26 cases, the arm vein in 38 cases, and the short saphenous vein in two cases. In 22 limbs (32%), angiography had shown an occluded segment of above-knee popliteal artery, and in these cases, local popliteal disobliteration was performed to receive the composite anastomosis and to provide additional outflow.

Results: The 2-year cumulative primary patency, secondary patency, and limb salvage rates were 68%, 73%, and 75%, respectively. Localized popliteal disobliteration did not compromise graft patency (P =.07, with log-rank test).

Conclusion: In the absence of sufficient autologous vein, patients needing bypass to crural arteries can be offered reconstruction with composite sequential grafting with satisfactory results. Furthermore, an occluded above-knee popliteal segment is not a contraindication for composite sequential bypass reconstruction.

Download full-text PDF

Source

Publication Analysis

Top Keywords

composite sequential
16
artery cases
16
autologous vein
12
above-knee popliteal
12
saphenous vein
12
cases
12
vein cases
12
vein
9
femorocrural bypass
8
bypass reconstruction
8

Similar Publications

Introduction: The utilization of sexual and reproductive health (SRH) services by males globally is significantly low despite their considerable sexual and reproductive health needs. This study aimed to understand the factors that influence the utilization of male sexual and reproductive health SRH services.

Methods: We used an explanatory sequential mixed methods research design, with qualitative description to explore the perceptions of males (15-49years) on the utilization of male SRH services in Anambra State, Nigeria.

View Article and Find Full Text PDF

The inherent heterogeneity, poor compatibility with polymers, and dark color of lignin limit its application in composites. In this study, original lignin (OL) was fractionated sequentially using four green organic solvents to obtain lignin fractions with different chemical structures. These well-defined lignin fractions were then blended with polybutylene succinate (PBS) to fabricate biocomposites.

View Article and Find Full Text PDF

Acoustic frequency comb generation on a composite diamond/silicon microcantilever in ambient air.

Microsyst Nanoeng

January 2025

Institute of Novel Semiconductors, State Key Laboratory of Crystal Materials, Shandong University, 27 South Shanda Road, Shandong, 250100, P. R. China.

Acoustic frequency combs (AFCs) contain equidistant coherent signals with unconventional possibilities on metrology. Previously, implementation of AFCs on mechanical microresonators with large air damping loss is difficult, which restricted their atmospheric applications. In this work, we explore the potentials of a composite diamond/silicon microcantilever for parametric generation of AFCs in ambient air.

View Article and Find Full Text PDF

Antigen affinity and site of immunization dictate B cell recall responses.

Cell Rep

January 2025

Department of Microbiology, Tumor and Cell Biology, Division of Virology and Immunology, Karolinska Institutet, 171 65 Solna, Sweden. Electronic address:

Protective antibodies against HIV-1 require unusually high levels of somatic mutations introduced in germinal centers (GCs). To achieve this, a sequential vaccination approach was proposed. Using HIV-1 antibody knockin mice with fate-mapping genes, we examined if antigen affinity affects the outcome of B cell recall responses.

View Article and Find Full Text PDF

Single-Injection Composite Tracer Achieves Intraoperative Dual-Tracing and Precise Localization of Sentinel Lymph Nodes.

ACS Appl Mater Interfaces

January 2025

Sixth People's Hospital, School of Medicine & School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200030, P. R. China.

The use of dual-tracer contrast agents in clinical applications, such as sentinel lymph node (SLN) identification, offers significant advantages including enhanced accuracy, sensitivity, as well as comprehensive and multimodal visualization. In the current clinical practice, SLNs are typically marked prior to surgical resection by multiple and sequential injections of two tracers, the radioactive tracer and methylene blue (MB) dye. This imposes physical and psychological burden on patients and medical staff.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!