A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Determination of a new phosphodiesterase V inhibitor, DA-8159, in plasma and urine by high-performance liquid chromatography. | LitMetric

Determination of a new phosphodiesterase V inhibitor, DA-8159, in plasma and urine by high-performance liquid chromatography.

J Pharm Biomed Anal

College of Pharmacy and Research Institute of Pharmaceutical Sciences, Seoul National University, San 56-1, Shinlim-Dong, Kwanak-Gu, Seoul 151-742, South Korea.

Published: October 2002

A high-performance liquid chromatographic (HPLC) method using liquid-liquid extraction for sample preparation was developed for the determination of a new phosphodiesterase V inhibitor, DA-8159, in rat plasma and urine using sildenafil citrate as an internal standard. A 100 microl aliquot of 0.1 M Na(2)CO(3) (containing sildenafil citrate, 3 microg/ml as free sildenafil) and a 1 ml aliquot of ether were added to a 100 microl aliquot of biological samples (urine samples were diluted 20 times with distilled water). After vortex centrifugation at 9000 x g for 3 min, the ether layer was collected and dried under nitrogen gas. The residue was reconstituted with a 150 microl aliquot of the mobile phase, centrifuged, and a 100 microl aliquot of the supernatant was injected onto a reversed-phase column. The mobile phases, 20 mM KH(2)PO(4) (pH 4.7):acetonitrile (70:30, v/v for plasma and tissue samples, and 75:25, v/v for urine samples), were run at a flow rate of 1.0 ml/min. The column effluent was monitored by an ultraviolet detector set at 292 nm. The retention times for DA-8159 and the internal standard were approximately 10.7 and 9.1 min, respectively, in plasma and tissue samples and the corresponding values in urine samples were 47 and 33 min. The detection limits for DA-8159 in rat plasma and urine were 20 and 100 ng/ml, respectively. The coefficients of variation of the assay were generally low: below 10% for plasma and 9.9% for urine. No interferences from endogenous substances were found.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0731-7085(02)00397-7DOI Listing

Publication Analysis

Top Keywords

microl aliquot
16
plasma urine
12
100 microl
12
urine samples
12
determination phosphodiesterase
8
phosphodiesterase inhibitor
8
inhibitor da-8159
8
high-performance liquid
8
da-8159 rat
8
rat plasma
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!