Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
A method using liquid chromatography coupled to tandem mass spectrometry is described for the determination of drugs of abuse in oral fluid. The method is able to simultaneously quantify amphetamines (amphetamine, methamphetamine, MDA, MDMA and MDEA), opiates (morphine and codeine), cocaine and benzoylecgonine. Only 200 micro of oral fluid is spent for analysis. The sample preparation is easy and consists of mixed mode phase solid-phase extraction. Reversed-phase chromatography is carried out on a narrow bore phenyl type column at a flow-rate of 0.2 ml/min. A gradient is applied ranging from 6 to 67.6% methanol with ammonium formate (10 mM, pH 5.0) added to the mobile phase. The column effluent was directed into a quadrupole-time-of-flight instrument by electrospray ionization, without the use of a splitter. A validation study was carried out. Recovery ranged from 52.3 to 98.8%, within-day and between-day precision expressed by relative standard deviation were less than 11.9 and 16.8%, respectively, and inaccuracy did not exceed 11.6%. The limit of quantification was 2 ng/ml (0.66 x 10(-5)-1.48 x 10(-5) M) for all compounds. Internal standards were used to generate quadratic calibration curves (r(2)>0.999). The method was applied to real samples obtained from suspected drug users. An interference was observed from the device used to sample the oral fluid, consequently this was excluded from the method which was validated on oral fluid obtained by spitting in a test-tube.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/s1570-0232(02)00400-2 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!