A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Reproducibility and accuracy of coronary calcium measurements with multi-detector row versus electron-beam CT. | LitMetric

Purpose: To methodically evaluate the reproducibility and accuracy of coronary arterial calcification measurements by using spiral multi-detector row and electron-beam computed tomography (CT) with a beating heart phantom.

Materials And Methods: A phantom was built to mimic a beating heart with coronary arteries and calcified plaques. The simulated vessels moved in a pattern similar to that of a beating heart. The phantom operated at a variety of pulse rates (0-140 beats per minute). The phantom was repeatedly scanned in various positions by using various protocols with electron-beam and multi-detector row CT scanners to assess interexamination variability. Statistical analysis was performed to determine significant differences in interexamination variability for various acquisition protocols.

Results: Electrocardiographically (EKG) gated volume coverage with spiral multi-detector row CT (2.5-mm collimation) and overlapping image reconstruction (1-mm increment) was found to significantly improve the reliability of coronary arterial calcium quantification, especially for small plaques (P <.05). Mean interexamination variability was reduced from 35% +/- 6 (SD) (Agatston score, standard electron-beam CT) to 4% +/- 2 (P <.05) (volumetric score, spiral EKG-gated multi-detector row CT).

Conclusion: By coupling retrospective gating with nearly isotropic volumetric imaging data, spiral multi-detector row CT provides better input data for quantification of coronary arterial calcium volume. Multi-detector row CT allows precise and repeated measurement of coronary arterial calcification, with low interexamination variability.

Download full-text PDF

Source
http://dx.doi.org/10.1148/radiol.2251010173DOI Listing

Publication Analysis

Top Keywords

multi-detector row
16
beating heart
12
reproducibility accuracy
8
accuracy coronary
8
coronary arterial
8
spiral multi-detector
8
interexamination variability
8
coronary
4
coronary calcium
4
calcium measurements
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!