Experimental verification of overdispersion in radioassay data.

Health Phys

Wadsworth Center, New York State Department of Health, Albany, NY 12201-0509, USA.

Published: October 2002

New evidence is provided suggesting that radioassay data are frequently overdispersed with respect to the Poisson distribution. Twelve cases of radioassay data were measured using commonly available detection systems. The data were analyzed using a limited version of the overdispersion model developed earlier. In that limit, the relationships between three overdispersed distributions were derived and discussed: beta-Poisson, negative binomial, and overdispersed Gaussian. Out of a total of 13 cases studied (12 measured plus one from the literature), 4 were consistent with the Poisson statistics at 90% confidence level while the remaining 9 were found overdispersed. This shows that the overdispersion is rather prevalent in radioassay. All three overdispersed distributions fitted the data very well. The overdispersion was attributed mostly to the excess fluctuations of the detection systems or, in 2 cases, sequential radioactive decay.

Download full-text PDF

Source
http://dx.doi.org/10.1097/00004032-200210000-00006DOI Listing

Publication Analysis

Top Keywords

radioassay data
12
detection systems
8
three overdispersed
8
overdispersed distributions
8
data
5
overdispersed
5
experimental verification
4
overdispersion
4
verification overdispersion
4
radioassay
4

Similar Publications

The present study aimed to investigate the hydrogeochemical patterns and contamination of the radiogeology, especially radon activity, related to geothermal aquifer properties and to perform a risk assessment of annual effective doses covering all hydrothermal spring attractions in Southern Thailand. Radon is an established lung carcinogen; especially longer term exposure to radioactive radon through inhalation could be a cause of lung cancer risk. Altogether 22 hydrothermal spring samples were collected from the six hydrothermal provinces in Southern Thailand in early November of 2023.

View Article and Find Full Text PDF

This study aims to explore the feasibility of applying the "Three-Low" technique (low injection rate, low iodine contrast volume, low radiation dose) in coronary CT angiography (CCTA). We prospectively collected data from 90 patients who underwent CCTA at our hospital between 2021 and 2024. The patients were randomly assigned to either the experimental group (n = 45) or the control group (n = 45).

View Article and Find Full Text PDF

Aim: To study the dosimetric behavior of dose computational algorithms in inhomogeneous medium using CMS XiO and MONACO treatment planning system (TPS) for 4 megavoltage (MV), 6 MV and 15 MV photon beam energies.

Material And Methods: Styrofoam blocks of thickness 1.90 cm, 3.

View Article and Find Full Text PDF

Dosimetric comparison of VMAT plans in preoperative short-course rectal radiotherapy.

Sci Rep

December 2024

Sir Run Run Shaw Hospital, School of Medicine, Zhejiang University, Hangzhou, 310000, China.

Recently, neoadjuvant short-course radiation therapy (SCRT) has emerged as a valid treatment option for patients with locally advanced rectal cancer (LARC). We assessed SCRT plans using volumetric-modulated arc therapy (VMAT) with Halcyon and Infinity medical linear accelerators (Linacs) and compared the plan quality and delivery efficiency across all cases. Thirty patients who underwent preoperative SCRT for LARC at the hospital were randomly selected.

View Article and Find Full Text PDF

Simulated low-dose dark-field radiography for detection of COVID-19 pneumonia.

PLoS One

December 2024

Chair of Biomedical Physics, Department of Physics & School of Natural Sciences, Technical University of Munich, Garching bei München, Germany.

Background: Dark-field radiography has been proven to be a promising tool for the assessment of various lung diseases.

Purpose: To evaluate the potential of dose reduction in dark-field chest radiography for the detection of the Coronavirus SARS-CoV-2 (COVID-19) pneumonia.

Materials And Methods: Patients aged at least 18 years with a medically indicated chest computed tomography scan (CT scan) were screened for participation in a prospective study between October 2018 and December 2020.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!