Spin disorder scattering in magnetic metallic alloys.

Phys Rev Lett

Instituto de Ciencia de Materiales de Aragón, Consejo Superior de Investigaciones Científicas and Universidad de Zaragoza, Spain.

Published: September 2002

Anomalous behavior of the resistivity at or just below the Néel temperature in antiferromagnetic metals is usually attributed to the formation of superzone gaps. However, we find that RMn12-xFex alloys which have no such gaps exhibit a similarly anomalous resistivity. We show that electron scattering by substitutional spin disorder can account for such behavior of itinerant magnets. This mechanism, which has not been studied before, leads to a relaxation rate that is proportional to x(12-x)m(2), where m is the staggered magnetization. Together with spin fluctuations, phonon, and impurity scattering, it accounts well for the resistivity data we obtain for HoMn12-xFex, for 0< or =x< or =9, in the temperature range of 4 to 400 K.

Download full-text PDF

Source
http://dx.doi.org/10.1103/PhysRevLett.89.106602DOI Listing

Publication Analysis

Top Keywords

spin disorder
8
disorder scattering
4
scattering magnetic
4
magnetic metallic
4
metallic alloys
4
alloys anomalous
4
anomalous behavior
4
behavior resistivity
4
resistivity néel
4
néel temperature
4

Similar Publications

Background: Diabetic peripheral neuropathy (DPN) is a common complication of diabetes. Proactive treatment options remain limited, which is exacerbated by a lack of sensitive and convenient diagnostics, especially early in disease progression or specifically to assess small fiber neuropathy (SFN), the loss of distal small diameter axons that innervate tissues and organs.

Methods: We designed, fabricated, tested, and validated a first-of-its-kind medical diagnostic device for the functional assessment of transdermal small fiber nerve activity.

View Article and Find Full Text PDF

Cerebral perfusion correlates with amyloid deposition in patients with mild cognitive impairment due to Alzheimer's disease.

J Prev Alzheimers Dis

February 2025

Department of Neurology, Tianjin Neurological Institute, Tianjin Medical University General Hospital, Tianjin, China, 154 Anshan Road Tianjin 300052, PR China; Department of Neurology, Tianjin Medical University General Hospital Airport Site, Tianjin 300052, PR China. Electronic address:

Background: Changes in cerebral blood flow (CBF) may contribute to the initial stages of the pathophysiological process in patients with Alzheimer's disease (AD). Hypoperfusion has been observed in several brain regions in patients with mild cognitive impairment (MCI). However, the clinical significance of CBF changes in the early stages of AD is currently unclear.

View Article and Find Full Text PDF

Objectives: Caffeine, a known neurostimulant and adenosine antagonist, affects brain physiology by decreasing cerebral blood flow. It interacts with adenosine receptors to induce vasoconstriction, potentially disrupting brain homeostasis. However, the impact of caffeine on blood-brain barrier (BBB) permeability to water remains underexplored.

View Article and Find Full Text PDF

Objective: The objective of this study was to evaluate the efficacy of a very-low-absorbable geraniol formulation, administered as a food supplement, in patients with irritable bowel syndrome (IBS) in a real-world setting in Italy.

Methods: This open-label study was conducted in Italy on patients diagnosed with IBS and treated for 4 weeks with 240 mg/day of Palmarosa essential oil, absorbed on 960 mg of ginger root powder to obtain a very-low-absorbable geraniol formulation. Baseline characteristics, including demographic and symptoms were recorded using the IBS Severity Scoring System (IBS-SSS).

View Article and Find Full Text PDF

: Accurate and reproducible spleen volume measurements are essential for assessing treatment response and disease progression in myelofibrosis. This study evaluates techniques for measuring spleen volume on abdominal MRI. : In 20 patients with bone marrow biopsy-proven myelofibrosis, 5 observers independently measured spleen volume on 3 abdominal MRI pulse sequences, 3D-spoiled gradient echo T1, axial single-shot fast spin echo (SSFSE) T2, and coronal SSFSE T2, using ellipsoidal approximation, manual contouring, and 3D nnU-Net model-assisted contouring comparing coefficients of variation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!