Fracture strength of denture base resins is of great concern, and many approaches have been used to strengthen acrylic resin dentures. Fracture resistance of six commercially available acrylic resin denture base materials were compared, through impact and transverse strength tests. Three rapid heat-polymerised resins (QC 20, Meliodent and Trevalon), two high-impact strength resins (Trevalon Hi and Lucitone 199) and a strengthened injection-moulded acrylic resin (SR Ivocap plus) were included in the study. Twenty acrylic resin test specimens were fabricated from each resin. For impact strength test, ten notched specimens were tested in a Charpy-type impact tester. The other ten specimens were used for transverse strength tests, deflection and modulus of elasticity values were also determined, which were assessed with three-point bending tests using an Universal Testing Machine. Impact test values showed significant differences among acrylic resins (F= 4.817 p = 0.0). SR Ivocap resin showed the highest impact strength values, followed by Trevalon Hi and Lucitone 199. The transverse strength test values were not significant when six acrylic resins were compared (F= 1.705 p = 0.151). High-impact resins can be recommended to increase the impact strength of denture base. If the cause of fracture is mechanical or anatomical, strengthened acrylic resins and conventional acrylic resins have similar fracture resistance.

Download full-text PDF

Source
http://dx.doi.org/10.1177/0885328202017001597DOI Listing

Publication Analysis

Top Keywords

acrylic resins
20
denture base
16
acrylic resin
16
fracture resistance
12
transverse strength
12
impact strength
12
acrylic
9
resins
9
resins fracture
8
strength
8

Similar Publications

Comparison of marginal fit between milled and three-dimensional printed polymethylmethacrylate prostheses for single crowns, anterior bridges, and pier abutment bridges: An in vitro study.

J Indian Prosthodont Soc

January 2025

Department of Prosthodontics and Implantology, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, Tamil Nadu, India.

Aim: The purpose of this in vitro study was to compare the marginal fit of various three-dimensional (3D) printed and milled polymethylmethacrylate (PMMA) dental prostheses.

Settings And Design: The study was conducted in an in vitro study setting.

Materials And Methods: With a sample size of 45 for each fabrication method, this investigation compared the marginal fit of milled (Group 1) and 3D printed (Group 2) PMMA dental prostheses across different designs.

View Article and Find Full Text PDF

Microenvironmental modulation breaks intrinsic pH limitations of nanozymes to boost their activities.

Nat Commun

December 2024

College of Engineering and Applied Sciences, Nanjing National Laboratory of Microstructures, Jiangsu Key Laboratory of Artificial Functional Materials, Nanjing University, Nanjing, Jiangsu, China.

Functional nanomaterials with enzyme-mimicking activities, termed as nanozymes, have found wide applications in various fields. However, the deviation between the working and optimal pHs of nanozymes has been limiting their practical applications. Here we develop a strategy to modulate the microenvironmental pHs of metal-organic framework (MOF) nanozymes by confining polyacids or polybases (serving as Brønsted acids or bases).

View Article and Find Full Text PDF

Background: The selection guideline for the implant-supported bar connectors (ISBC) of hybrid denture is lacking. This study investigated the maximum von Mises stress (vMS), stress distribution, and displacement of various geometric ISBC in mandibular hybrid dentures, as well as the maximum principal stress (σmax) in the acrylic resin part, through finite element analysis.

Methods: Four different geometric cross-sectional patterns for mandibular ISBC-L, Y, I, and Square-of equal volume, based on the "All-on-4" concept, were created.

View Article and Find Full Text PDF

Very high heat is generated during the polymerization of poly (methyl methacrylate) (PMMA) bone cement, which is used for implant fixation in orthopedic surgery. As such, it has been suggested that irrigating the bone cement layer in the surgical site with a saline solution is a way of cooling the layer. In this study, we aimed to determine the influence of irrigation with a saline solution on the flexural strength and the microstructure of the test specimens of two PMMA bone cement brands: Simplex P and FIX 1.

View Article and Find Full Text PDF

Objectives This study aimed to compare the shear bond strength of three resin cements (light-cured resin cement, pre-heated composite resin, and dual-cured self-adhesive resin cement) when bonding to lithium disilicate discs. Materials and methods Thirty-six discs made of lithium disilicate were fabricated and etched with 9.5% (HF), and 36 human premolars were collected and immersed in the acrylic molds, then randomly divided into three equal groups (n = 12): Group 1: light-cured resin cement, Group 2: pre-heated resin composite, and Group 3: dual-cured resin cement.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!