A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A comparison of the 24-gauge Sprotte and Gertie Marx spinal needles for combined spinal-epidural analgesia during labor. | LitMetric

Background: Prior experience with the combined spinal-epidural technique (CSE) for labor analgesia demonstrated a high (up to 14%) failure rate because of failure to obtain cerebrospinal fluid (CSF) or lack of response to appropriate doses of intrathecal sufentanil. The current study was designed to test whether a longer needle with a shorter side port (Gertie Marx needle; 127 mm long) would eliminate failures to obtain CSF compared with the needle we had used previously (Sprotte needle; 120 mm long).

Methods: Seventy-three parturients were randomly assigned to have a CSE performed with one of these two needles. After identifying the epidural space with an 18-gauge Touhy needle at the L2-L3 or L3-L4 interspace, the spinal needle was introduced through the Touhy needle until penetration of the dura was felt or until the needle was maximally inserted. If no CSF was obtained, the alternate needle was tried. After obtaining CSF, 10 microg sufentanil diluted in 1.8 ml saline was injected. Verbal pain scores (0-10) were obtained every 5 min for 30 min.

Results: Failure to obtain CSF occurred six times in the Sprotte group compared with none in the Gertie Marx group (P < 0.05). In all six failures in the Sprotte group, the Gertie Marx needle subsequently proved successful in obtaining CSF. There were no differences in pain scores between the groups.

Conclusions: The extra length of the 127-mm Gertie Marx needle resulted in a higher success rate for obtaining CSF when used in the CSE technique. Side port design was not a factor influencing success in this clinical setting.

Download full-text PDF

Source
http://dx.doi.org/10.1097/00000542-200209000-00009DOI Listing

Publication Analysis

Top Keywords

gertie marx
20
marx needle
12
obtaining csf
12
needle
11
combined spinal-epidural
8
side port
8
touhy needle
8
pain scores
8
sprotte group
8
csf
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!