A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Studies on properties and application of non-protected room temperature phosphorescence of propranolol. | LitMetric

Studies on properties and application of non-protected room temperature phosphorescence of propranolol.

Spectrochim Acta A Mol Biomol Spectrosc

Department of Chemistry, Tsinghua University, Beijing, People's Republic of China.

Published: August 2002

A direct and simple non-protected room temperature phosphorimetry (NP-RTP) for determine propranolol, which using I- as a heavy atom perturber and sodium sulfite as a deoxygenator, has been developed. The phosphorescence peak wavelength maxima lambda(ex)/lambda(em) = 288/494, 522 nm. The analytical curve of propranolol gives a linear dynamic range of 8.0 x 10(-8)-2.0 x 10(-5) mol l(-1) and a detection limit of 3 x 10(-8) mol l(-1). The influence of I- concentration on RTP lifetime of propranolol was studied and the luminescence kinetic parameters were calculated. It is found that the relation between I- concentration (x) and RTP lifetime (tau) can be expressed as tau = 1.25e(-0.477x) and the rate constants of phosphorescence emission k(p) was 0.800 per ms. The method was applied directly to determination of propranolol in urine and drug tablets with a satisfactory result. The recoveries were 96.6-97.4% and the relative standard deviation was 2% for the 1.00 x 10(-6)-4.00 x 10(-6) mol l(-1) propranolol in spiked urine sample.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s1386-1425(01)00729-6DOI Listing

Publication Analysis

Top Keywords

mol l-1
12
non-protected room
8
room temperature
8
concentration rtp
8
rtp lifetime
8
propranolol
6
studies properties
4
properties application
4
application non-protected
4
temperature phosphorescence
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!