A colorimetry-based retardation measurement (CBRM) method is presented. The specimen, between crossed polarizers, is illuminated with a white-light source. The retardation that is due to the birefringence of the specimen produces a white-light interference color. The x, y chromaticity coordinates of the color produced are measured with a spectrophotometer. The resulting x, y values are compared with a retardation x, y database that we obtained by measuring the retardation with an accurate Senarmont compensator and the x, y chromaticity values along the length of a 0-4-order quartz wedge. The technique was validated by the measurement of a variety of retardation plates. The retardation accuracy (mean error) of the CBRM method is shown to be 3.6 nm. The resolution is +/-0.2 nm, and the measurement range is 5-2150 nm. The method substitutes for a polariscope and eliminates errors associated with quarter-wave plates. The CBRM method does not utilize any moving parts and thus is fast and can be automated.

Download full-text PDF

Source
http://dx.doi.org/10.1364/ao.41.005290DOI Listing

Publication Analysis

Top Keywords

cbrm method
12
colorimetry-based retardation
8
retardation measurement
8
white-light interference
8
retardation
6
method
5
measurement
4
measurement method
4
method white-light
4
interference colorimetry-based
4

Similar Publications

Tailored meta-analysis uses setting-specific knowledge for the test positive rate and disease prevalence to constrain the possible values for a test's sensitivity and specificity. The constrained region is used to select those studies relevant to the setting for meta-analysis using an unconstrained bivariate random effects model (BRM). However, sometimes there may be no studies to aggregate, or the summary estimate may lie outside the plausible or "applicable" region.

View Article and Find Full Text PDF

Split-sciatic nerve surgery: A new microsurgical model in experimental nerve repair.

J Plast Reconstr Aesthet Surg

April 2018

Centre Hospitalier Universitaire Vaudois, Department of Plastic, Reconstructive and Hand Surgery, Lausanne, Vaud, Switzerland. Electronic address:

Introduction: Sciatic experimental surgery in rat often leads to hindlimb autophagy, with considerable ethical and research issues. In this work, the distal part of the sciatic nerve was split following the natural bifurcation between tibial and peroneal branches, before applying regenerative stem cells in a fibrin conduit on the peroneal segment. The new microsurgical model was tested in terms of animal morbidity and consistency of research outcomes, particularly comparing to the standard total sciatic axotomy procedure.

View Article and Find Full Text PDF

A colorimetry-based retardation measurement (CBRM) method is presented. The specimen, between crossed polarizers, is illuminated with a white-light source. The retardation that is due to the birefringence of the specimen produces a white-light interference color.

View Article and Find Full Text PDF

Monte Carlo calculations have previously been performed by Eckerman to evaluate the absorbed fractions of continuous sources of monoenergetic electrons in marrow cavities of human bone. The difference in scattering power of electrons in cortical bone (CB) and the red marrow (RM) was neglected. In the present work the Integrated Tiger Series and Electron-Gamma-Shower Monte Carlo codes were used to investigate the effect of topology of the bone and bone marrow interface on backscatter dose increase to the marrow.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!