Background: Paclitaxel (PXL)-eluting stents in animals cause incomplete healing and, in some instances, a lack of sustained suppression of neointimal growth. The present study tested the efficacy of a novel systemic delivery nanoparticle PXL for reducing in-stent restenosis.

Methods And Results: A saline-reconstituted formulation of PXL stabilized by albumin nanoparticles (nPXL) was tested in 38 New Zealand White rabbits receiving bilateral iliac artery stents. Doses of nPXL (1.0 to 5.0 mg/kg) were administered as a 10-minute intra-arterial infusion; control animals received vehicle (0.9% normal saline). In a follow-up chronic experiment, nPXL 5.0 mg/kg was given at stenting with or without an intravenous 3.5-mg/kg repeat nPXL dose at 28 days; these studies were terminated at 3 months. At 28 days, mean neointimal thickness was reduced (P< or =0.02) by doses of nPXL > or =2.5 mg/kg with evidence of delayed healing. The efficacy of a single dose of nPXL 5.0 mg/kg, however, was lost by 90 days. In contrast, a second repeat dose of nPXL 3.5 mg/kg given 28 days after stenting resulted in sustained suppression of neointimal thickness at 90 days (P< or =0.009 versus single dose nPXL 5.0 mg/kg and controls) with nearly complete neointimal healing.

Conclusions: Although systemic nPXL reduces neointimal growth at 28 days, a single repeat dose was required for sustained neointimal suppression. Thus, this novel systemic formulation of PXL may allow adjustment of dose at the stent treatment site and prove to be a useful adjunct for the clinical prevention of in-stent restenosis.

Download full-text PDF

Source
http://dx.doi.org/10.1161/01.cir.0000032141.31476.15DOI Listing

Publication Analysis

Top Keywords

npxl mg/kg
20
neointimal growth
12
novel systemic
12
dose npxl
12
npxl
9
sustained suppression
8
suppression neointimal
8
formulation pxl
8
doses npxl
8
neointimal thickness
8

Similar Publications

Background: Paclitaxel (PXL)-eluting stents in animals cause incomplete healing and, in some instances, a lack of sustained suppression of neointimal growth. The present study tested the efficacy of a novel systemic delivery nanoparticle PXL for reducing in-stent restenosis.

Methods And Results: A saline-reconstituted formulation of PXL stabilized by albumin nanoparticles (nPXL) was tested in 38 New Zealand White rabbits receiving bilateral iliac artery stents.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!