Ultrafast liquid chromatography/tandem mass spectrometry bioanalysis of polar analytes using packed silica columns.

Rapid Commun Mass Spectrom

Covance Laboratories Inc., 3301 Kinsman Boulevard, Madison, WI 53704, USA.

Published: December 2002

Ultrafast liquid chromatography/tandem mass spectrometry (LC/MS/MS) bioanalysis was demonstrated with the use of packed silica columns operated under elevated flow rates. A special effort has been made to achieve ultrafast analysis without sacrificing chromatographic resolution. Two multiple analyte/metabolites assays, (1) morphine/morphine-6-glucuronide(M6G)/morphine-3-glucuronide(M3G) and (2) midazolam/1'-hydroxymidazolam/4-hydroxymidazolam, were used to demonstrate the speed, sensitivity, peak shape and separation of the ultrafast methods utilizing silica columns. In both methods adequate chromatographic separation was a necessity because quantitation results would be otherwise compromised due to cross interference between different selected reaction monitoring (SRM) transitions. Baseline resolutions between morphine, M6G and M3G in human plasma extracts were achieved within 30 s on a 50 x 3 mm Betasil silica column operated at 4 mL/min of isocratic acetonitrile/water mobile phase. The total injection-to-injection cycle time was 48 s with a simple, single-autosampler/single-column setup, when a Shimadzu SIL-HT autosampler was used. Baseline resolution between 1'-hydroxymidazolam and 4-hydroxymidalolam in monkey plasma extracts was achieved within 33 s using similar conditions. Due to the absence of carry-over in this case, no rinsing of the injection needle was necessary, resulting in a cycle time of only 39 s/sample. These ultrafast methods were successfully used to analyze extracted biological samples and proved to be reproducible, reliable and generated equivalent pharmaco-kinetic (PK) results to those obtained by regular flow LC/MS/MS analysis to support discovery PK studies.

Download full-text PDF

Source
http://dx.doi.org/10.1002/rcm.762DOI Listing

Publication Analysis

Top Keywords

silica columns
12
ultrafast liquid
8
liquid chromatography/tandem
8
chromatography/tandem mass
8
mass spectrometry
8
packed silica
8
ultrafast methods
8
plasma extracts
8
extracts achieved
8
cycle time
8

Similar Publications

Sterols and triterpene alcohols exist in free and esterified forms in edible oils. To date, only few studies have determined the content of free or esterified sterols and triterpene alcohols using gas chromatography-flame ionization detection (GC-FID). In this study, analytical conditions were optimized using free and esterified sterol standards.

View Article and Find Full Text PDF

Expanding the chemical coverage of polar compounds in water analysis by coupling supercritical fluid with hydrophilic interaction chromatography high-resolution mass spectrometry.

Anal Chim Acta

March 2025

Van't Hoff Institute for Molecular Sciences (HIMS), University of Amsterdam, Science Park 904, 1098 XH, Amsterdam, the Netherlands; Centre for Analytical Sciences Amsterdam, Science Park 904, 1098 XH, Amsterdam, the Netherlands. Electronic address:

Background: Persistent and mobile organic compounds (PMOC) are of great concern for water quality and human health. The recent improvement and availability of high-resolution mass spectrometry in combination with liquid chromatography have widely expanded the potential of analytical workflows for their detection and quantitation in water. Given their high polarity, the detection of some PMOC requires alternative techniques to reversed-phase chromatography, such as hydrophilic interaction liquid chromatography (HILIC) and supercritical fluid chromatography (SFC).

View Article and Find Full Text PDF

Preparation of the immobilized α-adrenoceptor column by the ultra-high affinity protein pair CL7/Im7 and its application in drug-protein interaction analysis.

J Chromatogr B Analyt Technol Biomed Life Sci

January 2025

Northwest University Chang An Hospital, Faculty of Life Sciences and Medicine, Northwest University, Xi'an, Shaanxi 710069, China; Department of Clinical Pharmaceutics, Chang An District Hospital, Xi'an, Shaanxi 710118, China. Electronic address:

Immobilizing the target protein on a solid surface with controlled orientation, high specificity, and maintained activity is a proven strategy to enhance the stability of the protein. In this study, we employed an ultra-high affinity protein pair consisting of a mutant of colicin E7 Dnase and its corresponding inhibitor, immunity protein 7(Im7), to develop an immobilized α-adrenoceptor (α-AR) column. Briefly, we expressed α-AR fused with CL7 as a tag at its C-terminus in Escherichia coli cells.

View Article and Find Full Text PDF

Chiral Resolution and Chiroptical Properties of Hindered Tetraphenylethylene Helicates.

Org Lett

January 2025

Key Laboratory of Material Chemistry for Energy Conversion and Storage, Ministry of Education, School of Chemistry and Chemical Engineering, Huazhong University of Science and Technology, Wuhan 430074, China.

Hindered tetraphenylethylene (hTPE) helicates are resolved into two left-handed (M) and right-handed (P) isomers by linkage and removal of chiral auxiliary (1,2,5)-menthol, furnishing gram-scale hTPE enantiomers via flash silica column chromatography. hTPE helicate enantiomers bearing electron-accepting cyano and electron-donating triphenylamine groups can emit deep-blue CPL signals with a fluorescence quantum yield surpassing 50%. Full-color and white-light emission were achieved by blending them with dyes in a poly(methyl methacrylate) (PMMA) film.

View Article and Find Full Text PDF

Sequential separation of anti-diabetic drugs in the presence of melamine as impurity using chromatographic methods.

BMC Chem

January 2025

Pharmaceutical Chemistry Department, Faculty of Pharmacy, Nahda University, Sharq El-Nile, Beni-Suef, 62511, Egypt.

The study of green analytical chemistry has garnered significant attention in the context of mitigating global environmental contamination. In this study, we present two methodologies for environmentally friendly chromatography that enable simultaneous and specific determination of Saxagliptin (SAX), metformin (MET), and a pharmacopoeial impurity of MET known as melamine (MEL). The initial method employed in this study is High-Performance Thin Layer Chromatography (HPTLC), which utilized 60 F 254 silica gel-coated Mark HPTLC plates on aluminum sheets as the stationary phase.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!