A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Spectroscopic determination of protein concentrations from proteinase K digests. | LitMetric

Spectroscopic determination of protein concentrations from proteinase K digests.

Anal Biochem

Pharmaceutical Research Institute, Bristol-Myers Squibb Company, Syracuse, NY 13221, USA.

Published: August 2002

A method to determine protein concentrations and absorptivities based on absorbance measurements of proteinase K digests has been developed. Molar absorptivities of proteinase K digests at 56 degrees C can be predicted by using the following equation: epsilon (M)(280)=5318 x (No.of Trp) + 1227 x (No.of Tyr) + 133 x (No.of Cys-Cys). Protein concentration in the digest can be determined by dividing the corrected digest solution absorbance by the calculated epsilon(M)(280). The absorptivity of a native protein can then be calculated by dividing the absorbance of the intact protein solution by the concentration value obtained for the digest solution. Precision of the experimental data is within +/-3%, and the error of the method does not exceed 4.5%. The accuracy of determination does not depend on the size of the protein, Trp/Tyr ratio, presence or absence of certain chromophores, or other structural factors. The method requires amounts of protein routinely used for absorbance measurements.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0003-2697(02)00026-xDOI Listing

Publication Analysis

Top Keywords

proteinase digests
12
protein concentrations
8
absorbance measurements
8
concentration digest
8
digest solution
8
protein
7
spectroscopic determination
4
determination protein
4
concentrations proteinase
4
digests method
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!