Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Coherent-scatter computed tomography (CSCT) is a novel imaging method we are developing to produce cross-sectional images based on the low-angle (<10 degrees) scatter properties of tissue. At diagnostic energies, this scatter is primarily coherent with properties dependent upon the molecular structure of the scatterer. This facilitates the production of material-specific maps of each component in a conglomerate. Our particular goal is to obtain quantitative maps of bone-mineral content. A diagnostic x-ray source and image intensifier are used to acquire scatter patterns under first-generation CT geometry. An accurate measurement of the scatter patterns is necessary to correctly identify and quantify tissue composition. This requires corrections for exposure fluctuations, temporal lag in the intensifier, and self-attenuation within the specimen. The effect of lag is corrected using an approximate convolution method. Self-attenuation causes a cupping artifact in the CSCT images and is corrected using measurements of the transmitted primary beam. An accurate correction is required for reliable density measurements from material-specific images. The correction is shown to introduce negligible noise to the images and a theoretical expression for CSCT image SNR is confirmed by experiment. With these corrections, the scatter intensity is proportional to the number of scattering centers interrogated and quantitative measurements of each material (in g/cm3) are obtained. Results are demonstrated using both a series of poly(methyl methacrylate) (PMMA) sheets of increasing thickness (2-12 mm) and a series of 5 acrylic rods containing varying amounts of hydroxyapatite (0-0.400 g/cm3), simulating the physiological range of bone-mineral density (BMD) found in trabecular bone. The excellent agreement between known and measured BMD demonstrates the viability of CSCT as a tool for densitometry.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1118/1.1493216 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!