A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Analysis of organotin compounds by grignard derivatization and gas chromatography-ion trap tandem mass spectrometry. | LitMetric

The determination of organotin compounds in water using gas chromatography-tandem mass spectrometry (GC-MS-MS) is described. Several organotin derivatives were synthesized by the reaction of organotin chlorides with Grignard reagents such as methyl-, propyl- and pentylmagnesium halides. After the optimization of the GC-MS-MS conditions, several derivatizations with the Grignard reagents were compared by evaluating the molar responses and volatilities of the derivatives and derivatization yields. As a result, the derivatizing reagent of choice is pentylmagnesium bromide. Calibration curves for the mono-, di- and tributyltins and mono-, di- and triphenyltins with pentylmagnesium bromide were linear in the range of 0.5-100 pg of Sn. The instrumental detection limits of six organotins ranged from 0.20 to 0.35 pg of Sn. The recovery tests from water samples (500 ml) were performed by using sodium diethyldithiocarbamate (DDTC) as a complexing reagent. Except for monophenyltin, the absolute recoveries of organotins from pure water at 200 ng of Sn/l were satisfactory. The recoveries calibrated by surrogate compounds (perdeuterated organotin chlorides) ranged from 71 to 109%. The method detection limits ranged from 0.26 to 0.84 pg of Sn (500-ml sample). This method was applied to the recovery of organotins from river water and seawater. The calibrated recoveries were between 90 and 122%.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0021-9673(02)00534-4DOI Listing

Publication Analysis

Top Keywords

organotin compounds
8
mass spectrometry
8
organotin chlorides
8
grignard reagents
8
pentylmagnesium bromide
8
mono- di-
8
detection limits
8
analysis organotin
4
compounds grignard
4
grignard derivatization
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!