A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Hip displacement in spastic cerebral palsy: repeatability of radiologic measurement. | LitMetric

Hip displacement in spastic cerebral palsy: repeatability of radiologic measurement.

J Pediatr Orthop

Hugh Williamson Gait Laboratory and Murdoch Children's Research Institute, Royal Children's Hospital, Melbourne, Australia.

Published: October 2002

Radiologic measures of migration percentage (MP) and acetabular index (AI) taken from plain radiographs of the pelvis are the most commonly used tools for determining hip displacement and management options in children with cerebral palsy and spastic hip disease. This study determined interrater and intrarater reliability of MP and AI on pelvic radiographs chosen to represent a wide range of age (11 months to 8 years 5 months), MP (0%-56%), and AI (9 degrees -33 degrees ). The study demonstrated that an experienced rater would be expected to measure MP on a single radiograph to within +/-5.8% of the true value and a change in MP between two radiographs taken at different times to within +/-8.3% of the true value. Similarly for AI, the measurement error for a typical rater would be within +/-2.6 degrees on a single reading and +/-3.7 degrees if recording change between two occasions. The authors believe that the results indicating true change are acceptable in clinical practice, provided treatment decisions are based on a series of radiographs taken at 6-month intervals, methods and training are standardized, and consistent raters are used.

Download full-text PDF

Source

Publication Analysis

Top Keywords

hip displacement
8
cerebral palsy
8
true change
8
displacement spastic
4
spastic cerebral
4
palsy repeatability
4
repeatability radiologic
4
radiologic measurement
4
measurement radiologic
4
radiologic measures
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!