A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Factors influencing changes in articular cartilage following hemiarthroplasty in sheep. | LitMetric

This study examined the relationship between acetabular cartilage properties after hemiarthroplasty surgery and surgical variables including femoral head size and position. Nineteen sheep received unilateral hip arthroplasties and were euthanized one year post-operatively to harvest the femora and acetabula. Cartilage histology, biochemistry and material properties were determined from samples located in the superior load-bearing region. Femoral head size mismatch, leg length difference, anterior-posterior and medial lateral offset and anteversion were measured. In the acetabulum. substantial cartilage degradation occurred with widespread librillation and significant changes in the biochemical and material properties compared to the intact contralateral joint. Regression analyses on the surgical variables explained 75-80% of the changes in tissue biochemistry but did not explain the material changes. Head size mismatch and leg length difference were the most significant contributors of the five variables examined and therefore may be critical to successful outcome in hemiarthroplasty.

Download full-text PDF

Source
http://dx.doi.org/10.1016/S0736-0266(01)00182-6DOI Listing

Publication Analysis

Top Keywords

head size
12
surgical variables
8
femoral head
8
material properties
8
size mismatch
8
mismatch leg
8
leg length
8
length difference
8
factors influencing
4
changes
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!