We have developed a rapid automated immunoassay, using the BIACORE surface plasmon resonance (SPR) biosensor, to measure progesterone in bovine milk. The assay was designed as an inhibition assay with progesterone covalently immobilised to the carboxymethyl dextran matrix of a CM5 sensor chip. A fixed amount of monoclonal anti-progesterone antibody 39C5H7 was mixed 9:1 with the sample and the amount of free antibody was then determined using biomolecular interaction analysis (BIA) by injection of the mixture over the immobilised progesterone sensor surface. The assay was designed to cover the concentration range 0.5 to 50 ng/ml. The limit of detection (LOD) was 3.56 ng/ml. Reproducibility of the assay was very good with both intra-assay and inter-assay coefficients of variation <5%. As results become available within minutes of injection and the procedure involves fully automated instrumentation, we believe that this BIA assay for progesterone in milk could be used in-line in the milking parlour and, thus, provide an important tool for reproductive management of dairy cattle to detect heat and predict pregnancy.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0022-1759(02)00166-7DOI Listing

Publication Analysis

Top Keywords

progesterone bovine
8
bovine milk
8
assay designed
8
development validation
4
validation biosensor-based
4
biosensor-based immunoassay
4
progesterone
4
immunoassay progesterone
4
milk developed
4
developed rapid
4

Similar Publications

The objectives of this study were: (i) to evaluate the associations between postpartum health disorders, relative increase in walking activity (RIWA) and expression of behavioral estrus intensity captured by pedometers; (ii) to assess associations between RIWA and pregnancy in cows submitted to timed artificial insemination (TAI). Lactating dairy cows (n = 881) were enrolled in the study. Cows were submitted to a 5d TAI protocol with insertion of a progesterone device.

View Article and Find Full Text PDF

Background: The profitability of the beef industry is directly influenced by the fertility rate and reproductive performance of both males and females, which can be improved through selective breeding. When performing genomic analyses, genetic markers located on the X chromosome have been commonly ignored despite the X chromosome being one of the largest chromosomes in the cattle genome. Therefore, the primary objectives of this study were to: (1) estimate variance components and genetic parameters for eighteen male and five female fertility and reproductive traits in Nellore cattle including X chromosome markers in the analyses; and (2) perform genome-wide association studies and functional genomic analyses to better understand the genetic background of male and female fertility and reproductive performance traits in Nellore cattle.

View Article and Find Full Text PDF

Implementing accelerometer technologies in beef operations is an alternative to increase precision in estrous detection. We hypothesized that (1) the accelerometer algorithm has similar accuracy in detecting behavioral estrus as does visual observation of pressure-sensitive sensors (estrus patches) in grazing beef cows; (2) variables measured by the accelerometer, such as estrus intensity, are associated with hormonal, ovarian, and uterine variables monitored before, during, and after estrus; and (3) the accelerometer variables are associated with the probability of pregnancy in grazing beef cows submitted to embryo transfer (ET). Fifty cows were fitted with accelerometer and patches to detect estrus after a synchronization protocol in eight subsequent rounds.

View Article and Find Full Text PDF

Proper management of cattle reproduction has a major impact on the efficiency and profitability of dairy production. Ultrasound examination and transrectal palpation or the pregnancy-associated glycoprotein (PAG) test are currently the most commonly used methods for pregnancy diagnosis. However, alternative methods to those mentioned above are constantly being sought in order to minimise stress during the examination, the cost of veterinary services and to reduce the rate of errors in pregnancy diagnosis.

View Article and Find Full Text PDF

Sensitivity-enhanced competitive lateral flow immunoassays by polycaprolactone electrospun stacking pad: Estrous determination in whole blood.

Biosens Bioelectron

March 2025

Nanobiointeractions&Nanodiagnostics, Istituto Italiano di Tecnologia (IIT), Via Morego, 30, 16163, Genova, Italy. Electronic address:

Lateral flow assays (LFA) are widely adopted in point-of-care diagnostics across a spectrum of applications, due to their simplicity of use and cost-effectiveness. However, in complex biological matrices (e.g.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!