Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Unlabelled: The purpose of this study was to assess a 3-dimensional (3D)-only PET scanner (ECAT EXACT3D) for its use in the absolute quantification of myocardial blood flow (MBF) using H(2)(15)O.
Methods: Nine large white pigs were scanned with H(2)(15)O and C(15)O before and after partially occluding the circumflex (n = 4) or the left anterior descending (n = 5) coronary artery at rest and during hyperemia induced by intravenous dipyridamole. Radioactive microspheres labeled with either (57)Co or (46)Sc were injected during each of the H(2)(15)O scans, which allowed comparison between microsphere and PET measurements of regional MBF. PET analyses of 3D acquisition data were performed using filtered backprojection reconstruction and region-of-interest definition by factor and cluster analysis techniques and single-compartment model quantification.
Results: The Hanning filter applied in image reconstruction resulted in a left atrial blood volume recovery factor of 0.84 +/- 0.06. Differences between repeated measurements of recovery were small (mean, -0.8%; range, -6.6% to 3.6%). In 256 paired measurements of MBF ranging from 0.05 to 4.4 mL. g(- 1). min(-1), microsphere and PET measurements were fairly well correlated. The mean difference between the 2 methods was - 0.11 mL. g(-1). min(-1) and the limits of agreement (+2 SD) were -0.82 and 0.60 mL. g(-1). min(-1) (Bland-Altman plot).
Conclusion: Dynamic measurements with H(2)(15)O using a 3D-only PET tomograph provide reliable and accurate measurements of absolute regional MBF over a wide flow range. The 3D acquisition technique can reduce the radiation dose to the subject while maintaining adequate counting statistics.